4. Troubleshooting

If host PC fails to detect USB device, check the LED status on

the Remote unit. Make sure LED is illuminated. CAT6 cable is

recommended particularly if the length is longer than 100 ft.

Reboot the Host PC. Unplug the local unit from the Host PC

and connect it to a different USB port if available.

There are no field serviceable parts or circuits in the device.

Opening the device will void the warranty. If you think the

device is malfunctioning, please contact Hall Research.

5. Specifications

Local Unit

Upstream Port

USB Type A Male

Downstream Port

RJ 45 Jack

Power

Bus Powered

Remote Unit

Upstream Port

USB Type A Female

Power

External 5V Supply

Dimensions

2.6 x 1.4 x 0.8 inch (66 x 36 x 20 mm)

Interconnect

Cable

Standard category 5e/6 UTP or STP

CAT6 Recommended

Max Cable

Length

50 m (164 ft)

Power Supply

Universal AC input, 5vDC @ 2A output

Hall Research P/N 511-PA1015-1L

Operating

Temperature

32 to 150 °F (0 to 65 °C)