Caution, Notice – Hall Research UV232-8 User Manual

Page 8

Advertising
background image

Compact CAT5 Video/RS232 Splitters and Receivers

6

5. Connect the remote monitor and RS232 to the receiver unit and

attach the power supply to the receiver

CAUTION

Before plugging in the remote monitor, verify that the AC line is properly
wired and that a protective ground (green) wire is established with NO
potential difference between both the sender and receiver locations. The
splitter can tolerate up to 5 v peak-to-peak ground potential between the
two locations. Failure to ensure good grounding can result in erratic
operation and possible shock hazards or damage to your equipment.

NOTICE

Do not connect this unit to any LAN device such as network cards or hubs
as this may damage the UV232/UR232 and/or the LAN device. Use EIA/TIA
568B standard straight-through patch wiring as shown below. Do not use
crossover cables.

Figure 2.3

Advertising
This manual is related to the following products: