PC (VGA) & HD (YPbPr) AV with RS232 over Twisted-Pair Receivers
23
4.13 RS-232 Command Summary
The URA-232 consists of the following serial commands.
The unit communicates at 19200, No Parity, 8 Data Bits, 1 Stop Bit
To use the commands listed below, the unit must be in Adjustment-mode.
• Apply power to the receiver. Wait until all LED’s are turned off
• Press the SEL button once to enter Adjustment-mode.
• In Adjustment-mode, all three (3) LEDs will be turned ON.
• Send the RS-232 Serial command at 19200 baud, No parity, 8 Databits, 1
Stop bit, to get into the programming mode(e.g) Pass_Word<cr>
• All three (3) LED’s should be blinking and the device will have replied serially
with three (3) characters. ACK (0x06), CR (0x0D) and LF (0x0A).
• Once in this mode, the commands listed below may be used.
• Send the RS-232 Serial command EXIT<cr> to exit programming mode and
return to Adjustment-mode.
COMMAND
FUNCTION
VER?<cr>
Read firmware version – UNIT responds with “Ver x.y<cr><lf>” where x.y are the major and minor version numbers.
IO? <cr>
IO0<cr>
IO1<cr>
Query discrete input type – UNIT responds with “IO1” or “IO0”
Set discrete input type to Contact Closure
Set discrete input type to Voltage (5-30 vDC)
FDFT<cr>
Factory default – UNIT responds with “Are you sure (Y,N)?”, a “Y<cr>” response will result in a “Factory Defaults”
response. Any other response to the question or failure to answer with in 8 seconds will result in a “Cancelled”
response.
NO CONTACT Closure is the factory default.
RSTU<cr>
Unit reset – UNIT will respond with “Reset URA<cr><lf>”
Pass_Word<cr>
Password to get into the programming mode
EXIT<cr>
Exit the programming mode and back to the adjustment mode
RESERVED COMMANDS
Re<cr>
RESERVED FOR HALL RESEARCH
RE<cr>
RESERVED FOR HALL RESEARCH
We<cr>
RESERVED FOR HALL RESEARCH
WE<cr>
RESERVED FOR HALL RESEARCH
RST0<cr>
RST1<cr>
RST2<cr>
RST3<cr>
Reset Video Compensation to 0
Reset RED Skew to 0
Reset GREEN Skew to 0
Reset BLUE Skew to 0
INC0<cr>
INC1<cr>
INC2<cr>
INC3<cr>
Increment Video Compensation by 1
Increment RED Skew Correction by 1
Increment GREEN Skew Correction by 1
Increment BLUE Skew Correction by 1
DEC0<cr>
DEC1<cr>
DEC2<cr>
DEC3<cr>
Decrement Video Compensation by 1
Decrement RED Skew Correction by 1
Decrement GREEN Skew Correction by 1
Decrement BLUE Skew Correction by 1
RD0? Or RD0<cr>
RD1? Or RD1<cr>
RD2? Or RD2<cr>
RD3? Or RD3<cr>
Read HF Compensation & Gain Settings
UNIT responds with “x, y<cr><lf>”
Read Skew Correction Values (RGB)
UNIT responds with “R, G, B<cr><lf>”
RDUS<cr>
Read Unit Settings
WG? <cr>
WG1<cr>
WG0<cr>
Query Wire Gauge setting – UNIT responds with “23G” or “24G”
Set 24 AWG wire size
Set 23 AWG wire size