PRELIMINARY EXAMINATION

Remove the instrument from the packing material
and examine it carefully to make sure that no dam-
age has occurred during shipment. If there is any
damage, immediately notify your Dealer.

Each meter is supplied complete with battery and
instructions.

Note: Conserve all packing material until the instru-

ment has been observed to function correctly.
Any defective item must be returned in its
original packing.

SPECIFICATIONS

Range

-50.0 to 150.0°C / -58.0 to 302.0°F

Resolution

0.1°C / 0.1°F

Accuracy

±0.3°C (-20 to 90°C) / ±0.5°C (outside)

±0.5°F (-4 to 1942°F) / ±1°F (outside)

Probe

Stainless steel, 1 m (3.3’) cable

Environment

0 to 50°C (32 to 122°F);

RH max 95%

Battery Type

1x1.5V AAA alkaline

Battery Life

Approx. 3 years of use

Dimensions

106 x 58 x 19 mm (4.1x5.2x0.7")

Weight

80 g (2.8 oz.)

GENERAL DESCRIPTION

Checktemp

®

1 is a high accuracy thermometer with a

1 m (3.3') cable between the meter and the probe.
The probe utilizes a hightech NTC thermistor sensor to
measure the temperature. Thermistors make it possible
to obtain extremely high accuracy in a very short period
of time.
Thanks to its sharp tip, the probe can easily penetrate
semisolid products such as fruits, vegetables and
cheese, making routine controls simple and quick for
both incoming and outgoing goods.
Moreover, the AISI 316 stainless steel material of the
probe is in compliance with food regulations.
The Calibration-Check

®

function ensures always accu-

rate measurements: simply activate the “test” switch
and the internal calibration test device will simulate a
0.0°C (32.0°F) signal that has to be read on the LCD
within a range of ±0.3°C (±0.5°F). This assures the
user that the reading is reliable and accurate, every time.
Two models are available:
HI 98509 (

Checktemp

®

1 C) reads temperature in °C

unit

HI 98510 (

Checktemp

®

1 F) reads temperature in °F

unit

Advertising