19

18

ACCESSORIES

K-TYPE THERMOCOUPLE PROBES

with integral handle, 1 m (3.3') cable & mini-connector

HI 766A

Roller surface probe, max 320°C/600°F

HI 766B

Surface probe, max 650°C/1200°F

HI 766B1

90º surface probe, max 450°C/840°F

HI 766B2

Spring-loaded, surface probe, max 900°C/1650°F

HI 766B3

Spring-loaded, small surface probe w/insulated shaft

HI 766C

Penetration probe, max 900°C/1650°F

HI 766C1

Ultra-fast Penetration probe, max 300°C/570°F

HI 766D

Air probe, max 300°C/570°F

HI 766E1

General purpose probe, max 900°C/1650°F

HI 766F

High temperature, flexible wire probe without handle

HI 766F1

Flexible wire probe w/o handle, max 480°C/900°F

HI 766TR1

Penetration probe, max 250°C/482°F

HI 766TR2

Penetration long probe, max 250°C/482°F

HI 766TV1

Pipe clamp probe, max 200°C/390°F

with detachable handle & mini-connector (to be used in con-
junction with the HI 766HD probe handle)

HI 766PA

Roller surface probe, max 320°C/600°F

HI 766PB

Surface probe, max 650°C/1200°F

HI 766PC

Penetration probe, max 900°C/1650°F

HI 766PD

Air probe, max 300°C/570°F

HI 766PE1

General purpose probe, max 900°C/1650°F

grill surface probe

HI 766B4

Grill surface probe with 70 cm (27.6’’) cable (protected
with stainless steel jacket), max 250°C/482°F

HI 7664B4S

Spare stainless steel sensor for HI 766B4 probe

OTHER ACCESSORIES

HI 710007 / 8

Shockproof rubber boot, blue / orange

HI 710018

Spare protective case

HI 766EX

Extension cable for K-type probes

HI 92000

Windows

®

compatible software

HI 920011

Serial cable for PC connection

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the
environment in which they are used. Operation of these instruments in residential
area could cause unacceptable interferences to radio and TV equipments, requiring
the operator to take all necessary steps to correct interferences. Any variation intro-
duced by the user to the supplied equipment may degrade the instruments' EMC
performance. To avoid electrical shock, do not use these instruments when voltages
at the measurement surface exceed 24 Vac or 60 Vdc. To avoid damages or burns,
do not perform any measurement in microwave ovens.

USER CALIBRATION

(Not for HI 93530, HI 93531 and HI 93532 models)
The meters can be calibrated at 0°C by using an ice bath.
• Prepare an ice bath with approximately equal volumes of distilled

water and chopped ice made from distilled water.

• Immerse the temperature probe in the center of the ice bath,

taking care not to touch the ice with the probe tip.

• Ensure that the meter is measuring a temperature within ±3°C.
• To enter the Calibration mode, press and hold the CAL button for

about 5 seconds.

• The CAL tag turns on to indicate that the

Calibration mode has been entered.

Note: If the measurement is outside the

±3°C window, the meter does not
enter Calibration mode.

• When the meter reaches the stability condition, which is detected

when the measurement remains within ±0.2°C for 5 seconds,
the calibration is accepted and the reading becomes 0°C (32°F).

• The meter then automatically returns to normal mode.
Note: To exit the Calibration mode at any time, press the CAL key.
Note: User calibration cannot be entered in T1-T2 mode.
Note: User calibration is only performed on the current channel

displayed (T1 or T2).

FACTORY RECALIBRATION

All Hanna thermometers have been accurately pre-calibrated at the
factory.
It is generally recommended to have all thermometers recalibrated at
least once a year.
For an accurate recalibration, contact your nearest Hanna Customer
Service Center.

Note: To clean the meters, do not use aggressive detergents. It is

recommended to use water.