Hanna Instruments HI 9060 User Manual

Hi 9060

Advertising
background image

WARRANTY

PRELIMINARY EXAMINATION

GENERAL DESCRIPTION

FUNCTIONAL DESCRIPTION

SPECIFICATIONS

Instruction Manual

HI 9060

Portable Waterproof

Microprocessor-based

Thermistor

Thermometer

Remove the instrument from the packing material and exam-
ine it carefully to make sure that no damage has occurred
during shipping. If there is any noticeable damage, notify
your Dealer or the nearest Hanna Office.

Note: Save all packing materials until you are sure that the

instrument functions correctly. Any defective item must
be returned in the original packaging together with
the supplied accessories.

Range
Resolution
Accuracy

Typical EMC
Deviation
Battery Type
Life
Probe

(included)

Environment
Dimensions
Weight

1. Battery cover
2. Temperature probe connector
3. Liquid Crystal Display
4. ON/OFF Key
5. Measuring unit selection key
6. HOLD measurement key
7. HI/LO values reset key

HI 9060 is a waterproof, microprocessor-based, thermistor
thermometer, ideal for use in wet and humid environments.
The meter is also provided with low battery detection and
BEPS (Battery Error Preventing System), which turns the unit
off when the batteries are discharged avoiding erroneous
readings caused by low battery level.
HI 9060 features include a dual-level LCD for simultaneously
displaying of maximum and minimum measured tempera-
tures, °C/°F selection button and hold function.

The meter is supplied complete with HI 765BL temperature
probe, 4 x 1.5V AA batteries and instruction manual.

1. Current temperature value
2. HOLD indicator
3. Low Battery indicator
4. Minimum temperature value
5. Maximum temperature value
6. Measuring scale, °C or °F

CE DECLARATION OF CONFORMITY

IST9060R1 06/05

All Hanna Instruments meters are warranted for two years against de-
fects in workmanship and materials when used for their intended purpose
and maintained according to instructions. Sensors and probes are war-
ranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed mainte-
nance are not covered.
If service is required, contact the dealer from whom you purchased the instru-
ment. If under warranty, report the model number, date of purchase, serial
number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer Ser-
vice department, then return the instrument with the Authorization # included
along with shipment costs prepaid. If the repair is not covered by the war-
ranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for com-
plete protection.

-50.0 to 150.0°C / -58.0 to 302.0°F

0.1°C / 0.1°F

±0.4°C / ±0.8°F

for 1 year, excluding probe error

±1°C / ±2°F

with HI 765BL probe

4 x 1.5V AA (IEC LR6)

approx. 3000 hours of continuous use

HI 765BL with 1 m (3.3') cable

-10 to 50ºC (14 to 122ºF); RH 100%

196 x 80 x 60 mm (7.7x3.1x2.4")

500 g (1.1 lb.)

w w w . h a n n a i n s t . c o m

Hanna Instruments reserves the right to modify the design, construction and

appearance of its products without advance notice.

Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary information
for correct operation. Please read it carefully before using the
meter.
If you need additional technical information, do not hesitate
to e-mail us at [email protected].
This instrument is in compliance with the directives.

Advertising