Hanna Instruments HI 8757 User Manual

Page 2

Advertising
background image

ACCESSORIES

OPERATIONAL GUIDE

Remove the battery cover on the back of the thermometer.
Unwrap the supplied 9V battery, connect it to the battery clip
and reattach the cover.
Connect the temperature probe to the connector on the top of
the meter.

To switch ON, turn the rotary knob to
the ºC or ºF position (depending on
the model).

The meter displays the percentage
indication of the remaining battery
life for a few seconds, and then enters
measurement mode.

If a temperature probe is plugged in, the meter displays the
measured temperature either in °C (HI 8757) or °F (HI
8758), automatically switching to the resolution suitable to
the temperature range; i.e. 0.1° up to 199.9°C (399.9°F),
or 1° above.
If no probe is plugged in, or if read-
ing is over-range, the display shows
flashing dashes.
If a measurement is slightly over the range of the meter
specifications, the display flashes the closest full-scale value.

To switch the thermometer OFF, turn
the rotary knob to OFF.

FACTORY RECALIBRATION

All Hanna thermometers have been accurately pre-calibrated
at the factory. It is generally recommended to have all
thermometers recalibrated at least once a year.
For an accurate annual recalibration, contact your dealer or
the nearest Hanna Service Center.

BATTERY REPLACEMENT

The instrument is powered by a 9 V battery and is provided
with Battery Error Prevention System (BEPS), which turns the
unit off when a low battery signal is detected.
When the battery level is less than
10%, a warning symbol blinks on
the display to indicate a low battery
condition.
It is recommended to replace the battery as soon as the low
battery condition is detected.
Remove the cover on the meter's back by applying pressure in
the indicated direction. Unplug the rundown battery and
replace it with a new one.

Battery replacement must only take place in a nonhazardous
area using a 9V alkaline battery.

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the environment in which
they are used.

Operation of these instruments in residential areas could cause unacceptable interference to radio and
TV equipment, requiring the operator to take all necessary steps to correct interference.

Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance.

To avoid electrical shock, do not use these instruments when voltage at the measurement surface
exceeds 24 Vac or 60 Vdc.

To avoid damage or burns, do not perform any measurement in microwave ovens.

CE DECLARATION OF CONFORMITY

K-TYPE THERMOCOUPLE PROBES

with integral handle, 1 m (3.3’) cable & mini-connector,
for several applications:
HI 766A

Roller surface, max 320°C/600°F

HI 766B

Surface, max 650°C/1200°F

HI 766B1

90º surface, max 450°C/840°F

HI 766B2

Spring-loaded, surface, max 900°C/1650°F

HI 766B3

Spring-loaded, small surface probe
with insulated shaft, max 200°C/390°F

HI 766C

Penetration, max 900°C/1650°F

HI 766C1

Ultra-fast penetration, max 300°C/570°F

HI 766D

Air probe, max 300°C/570°F

HI 766E1

General purpose probe, max 900°C/1650°F

HI 766E2

General purpose probe, max 900°C/1650°F

HI 766F

High temperature, flexible wire probe
without handle, max 1100°C/2000°F

HI 766F1

Flexible wire probe without handle, max
480°C/ 900°F

HI 766TR1

Penetration, max 250°C/482°F

HI 766TR2

Penetration long probe, max 250°C/482°F

HI 766TV1

Pipe clamp probe, max 200°C/390°F

with detachable handle & mini-connector

(to be used

in conjunction with the HI 766HD probe handle):

HI 766PA

Roller surface, max 320°C/600°F

HI 766PB

Surface, max 650°C/1200°F

HI 766PC

Penetration, max 900°C/1650°F

HI 766PD

Air, max 300°C/570°F

HI 766PE1

General purpose, max 900°C/1650°F

HI 766PE2

General purpose, max 900°C/1650°F

grill surface probe:
HI 766B4

Grill surface probe with 70 cm (27.6’’)
cable (protected with stainless steel jacket),
max 250°C/482°F

HI 7664B4S

Spare stainless steel sensor for HI766B4 probe

OTHER ACCESSORIES

HI 710002

Soft carrying case

HI 710009

Shockproof rubber boot, blue

HI 710010

Shockproof rubber boot, orange

HI 721316

R

UGGED

carrying case

HI 766EX

Extension cable for K-type probes

HI 766HD

Rugged thermocouple probe handle with
1m (3.3') cable fitted with mini-connector

ACCESSORIES

IST8757R1 06/05

Advertising
This manual is related to the following products: