Hanna Instruments HI 981504 User Manual

Ph, tds, temperature monitor

Advertising
background image

Instruction Manual

HI 981504

pH, TDS, Temperature

Monitor

w w w . h a n n a i n s t . c o m

WARRANTY

These instruments are guaranteed for two years against
defects in workmanship and materials when used for their
intended purpose and maintained according to instructions.
Probes are guaranteed for one year. This warranty is
limited to repair or replacement free of charge. Damages due to
accidents, misuse, tampering or lack of prescribed maintenance
are not covered. If service is required, contact the dealer from
whom you purchased the instrument. If under warranty, report
the model number, date of purchase, serial number and the
nature of the failure. If the repair is not covered by the
warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain
a Returned Goods Authorization Number from the Customer
Service department and then send it with shipment costs
prepaid. When shipping any instrument, make sure it is
properly packaged for complete protection.

All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments.

Dear Customer,
Thank you for choosing a Hanna product.
Please read carefully this instruction manual before using the
meter. If you need additional technical information, do not
hesitate to e-mail us at [email protected].
These instruments are in compliance with the

directives.

PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine
it carefully. If any damage has occurred during shipment,
immediately notify your Dealer or the nearest Hanna Customer
Service Center.
Each meter is supplied with:

• HI 1286 pH electrode
• HI 7634 TDS probe & temperature probe (fixed)
• pH 4 & pH 7 buffer sachets, 1 pc. each
• HI 70032 (1382 ppm) sachet for HI 981504/5 or

HI 70442 (1500 ppm) sachet for HI 981504/7

• HI 700661 cleaning solution sachet, 2 pcs
• Screwdriver, 12 Vdc power adapter & instructions

Note: Conserve all packing material until the instrument has

been observed to function correctly. Any defective item
must be returned in its original packing.

GENERAL DESCRIPTION

HI 981504 has been designed for continuously and simulta-
neously monitoring pH, TDS and temperature.
Simply install the HI 981504 above the sample to be tested,
plug the instrument to the mains and immerse the probes.
pH, TDS and temperature measurements will be simultaneously
displayed on three backlit LCDs.
The user can easily select the temperature unit (°C or °F)
through a switch on the rear panel.
The HI 1286 gel-filled pH electrode is provided with a water-
proof sheath to protect the BNC connector. The unique design of
the electrode provides longer life even in aggressive solutions.
The HI 7634 TDS probe is easy to clean and requires little
maintenance.
Measurements are accurate and the meter can be calibrated at
one or two points for pH, and at a single point for TDS.
Temperature range is factory calibrated.
Two models are available:
• HI 981504/5 with 0.5 TDS factor
• HI 981504/7 with 0.7 TDS factor

1. Backlit LCD for pH readings
2. pH calibration trimmers
3. Backlit LCD for TDS readings
4. TDS calibration trimmer
5. Backlit LCD for temperature readings
6. BNC connector (pH electrode)
7. Protective sheath for BNC connector
8. HI 1286 pH electrode
9. HI 7634 TDS probe (fixed)

10. Temperature probe (fixed)
11. 12 Vdc power adapter
12. Power supply connector

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the environment in
which it is used. Operation of these instruments in residential areas could cause unacceptable
interferences to radio and TV equipment. The glass bulb at the end of the electrode is
sensitive to electrostatic discharges. Avoid touching the bulb at all times. During operation,
ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic
discharges. Any variation introduced by the user to the supplied equipment may degrade the
instruments’ EMC performance. To avoid electrical shock, do not use this instrument when
voltage at the measurement surface exceeds 24 Vac or 60 Vdc. To avoid damage or burns, do
not perform any measurement in microwave ovens.

FUNCTIONAL DESCRIPTION

SPECIFICATIONS

Range

pH

0.0 to 14.0 pH

TDS

0 to 1990 ppm

Temperature

-10.0 to 60.0°C / -14.0 to 140.0°F

Resolution

pH

0.1 pH

TDS

10 ppm

Temperature

0.1°C / 0.1°F

Accuracy

pH

±0.2 pH

TDS

±2% f.s.

Temperature

±0.3°C / ±0.5°F

TDS Factor

0.5 (

HI 981504/5

) or 0.7 (

HI 981504/7

)

Calibration

pH

Manual, 2 point, through trimmers

TDS

Manual, 1 point, through trimmer

Temperature

Factory calibrated

Probes

pH

HI 1286 (included)

TDS

HI 7634 (fixed)

Temperature

Stainless steel, 2 m cable (fixed)

Temperature

Automatic, 5 to 50°C (41 to 122°F),

Compensation

for TDS readings only

Environment

0 to 50 °C (32 to 122°F); RH max 95%

Power Supply

12 Vdc power adapter (included)

Dimensions

160 x 110 x 35 mm (6.3x4.3x1.4’’)

Weight

560 g (1.2 lb.)

Hanna Instruments reserves the right to modify the design,

construction and appearance of its products without advance notice.

Advertising