Hanna Instruments HI 96743 User Manual

Hanna Instruments Measuring instruments

Advertising
background image

INSTRUCTION MANUAL

HI 96743

HI 96743

HI 96743

HI 96743

HI 96743

Iron LR and pH

ISM

w w w . h a n n a i n s t . c o m

Preliminary examination:

Please examine this product carefully. Make sure that the instrument is
not damaged. If any damage occured during shipment, please notify
your Dealer.
Each HI 96743 Ion Selective Meter is supplied complete with:
• Two Sample Cuvettes and Caps
• 9V Battery
• Instruction Manual
Note:

save all packing material until you are sure that the instrument
works correctly. Any defective item must be returned in its original
packing.

For more details about spare parts and accessories
see “Accessories”.

Dear Customer,
Thank you for choosing a Hanna product. This manual will provide you
with the necessary information for the correct use of the instrument. Please
read it carefully before using the meter. If you need additional technical
information, do not hesitate to e-mail us at [email protected].

Technical specifications:

Range

Iron LR

0.00 to 1.60 mg/L

pH

6.5 to 8.5

Resolution

0.1 pH
0.01 mg/L Iron LR

Accuracy

Iron LR

±0.01 mg/L ±8% of reading @ 25°C

pH

±0.1 pH @ 25°C

Typical EMC Dev.

±0.01 mg/L Iron LR
±0.1 pH

Light Source

Tungsten lamp

Light Detector

Silicon Photocell with narrow band interference
filter @ 525 nm

Method

For Iron LR: Adaptation of the TPTZ method. The reaction
between iron and the reagent causes a violet tint in the
sample.
For pH: Phenol red method. The reaction with reagents
causes a red tint in the sample.

Environment

0 to 50°C (32 to 122°F);
max 95% RH non-condensing

Battery Type

1 x 9 volt

Auto-Shut off

After 10' of non-use in measurement mode;
after 1 hour of non-use in calibration mode;
with last reading reminder.

Dimensions

192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)

Weight

360 g (12.7 oz.).

1. RANGE/GLP/ key: press to change the paramter, press and hold

for three seconds to enter

GLP mode. In calibration mode press to edit

the date and time.

2. CAL CHECK key: press to perform the validation of the meter, or

press and hold for three seconds to enter

calibration mode.

3. ZERO/CFM key: press to zero the meter prior to measurement, to

confirm edited values or to confirm factory calibration restore.

4. READ/ /TIMER key: In

measurement mode, press to make a

measurement, or press and hold for three seconds to start a pre-
programmed countdown prior to measurement. In

GLP mode press to

view the next screen.

5. ON/OFF key: to turn the meter on and off.
6. Liquid Crystal Display (LCD)
7. Cuvette alignment indicator
8. Cuvette holder

DISPLAY ELEMENTS DESCRIPTION:

Functional description:

1. The measuring scheme (lamp, cuvette, detector), appears during

different phases of zero or reading measurement

2. Error messages and warnings
3. The battery icon indicates the change state level of the battery
4. The hourglass appears when an internal check is in progress
5. Status messages
6. The chronometer appears when the reaction timer is running
7. The month, day and date icons appear when a date is displayed
8. Four digit main display
9. Measuring units
10. Four digit secondary display

Light High:

There is too much light to perform

a measurement. Please check the preparation of
the zero cuvette.

Light Low:

There is not enough light to perform

a measurement. Please check the preparation of
the zero cuvette.

No Light:

The instrument cannot adjust the

light level. Please check that the sample does
not contain any debris.

Errors and warnings:

ON ZERO READING:

ON SAMPLE READING:

DURING CALIBRATION PROCEDURE:

OTHER ERRORS AND WARNINGS:

Cap error:

Appears when external light enters

in the analysis cell. Assure that the cuvette cap
is present.

Cooling lamp:

The instrument waits for the

lamp to cool down.

Battery low:

The battery must be replaced

soon.
Dead battery:

This indicates that the battery

is dead and must be replaced. Once this
indication is displayed, normal operation of the
instrument will be interrupted. Change the
battery and restart the meter.

Standard Low:

The standard reading is less

than expected.

Standard High:

The standard reading is higher

than expected.

Inverted cuvettes:

The sample and the zero

cuvette are inverted.

Zero:

A zero reading was not taken. Follow the

instructions of the measurement procedure for
zeroing the meter.

Under range:

A blinking “0.00” indicates that

the sample absorbs less light than the zero
reference. Check the procedure and make sure
you use the same cuvette for reference (zero)
and measurement.
Over Range:

A flashing value of the maximum

concentration indicates an over range condition.
The concentration of the sample is beyond the
programmed range: dilute the sample and
re-run the test.

1• Turn the meter on by pressing ON/OFF.
2• When the beeper sounds briefly and the

LCD displays dashes and “P1” (Iron LR) or
“P2” (pH) the meter is ready. The code
that appears on the secondary display is
the one of the last selected parameter. If
necessary, press RANGE/GLP/ to
change parameter. The blinking “ZERO”
indicates that the instrument needs to
be zeroed first.

3• For Iron LR: Fill one graduated mixing

cylinder up to the 25 mL mark with
deionized water. Add the content of one
packet of HI 93746-0 reagent, close the
cylinder and shake well for 30 seconds.
This is the blank. Fill a cuvette with 10
mL of the blank up to the mark and
replace the cap.
For pH: fill the cuvette with 10 mL of
unreacted sample, up to the mark, and
replace the cap.

4• Place the cuvette into the holder and

ensure that the notch on the cap is
positioned securely into the groove.

5• Press ZERO/CFM and the lamp, cuvette

and detector icons will appear on the
display, depending on the measurement
phase.

6• After a few seconds the display will show

“-0.0-”

. The meter is now zeroed and

ready for measurement.

7• Remove the cuvette.
8• Iron LR: Fill one graduated mixing cylinder

up to the 25 mL mark with the sample.
Add the content of one packet of HI 93746-
0

reagent, close the cylinder and shake

well for 30 seconds. Fill a cuvette with
10 mL of the reacted sample up to the
mark and replace the cap.
pH: fill the cuvette with 10 mL of unreacted
sample, up to the mark, add 5 drops of
HI 93710-0

, replace the cap and invert

several times to mix.

9• Replace the cuvette into the holder and

ensure that the notch on the cap is
positioned securely into the groove.

10•Press and hold READ/ /TIMER for three

seconds

.

The display will show the

countdown prior to measurement. The
beeper is playing a beep at the end of
countdown period.

Dead battery:

This indicates that the battery

is dead and must be replaced. Once this
indication is displayed, normal operation of the
instrument will be interrupted. Change the
battery and restart the meter.

Measurement procedure:

Measurement

4

5-6

8

10

2

3