Hanna Instruments HI 93713 User Manual

Hanna Instruments Measuring instruments

Advertising
background image

Instruction Manual

HI 93713

Phosphate Low Range

ISM

w w w . h a n n a i n s t . c o m

This Instrument is in

Compliance with the CE Directives

Hanna Instruments reserves the right to modify the design, construction

and appearance of its products without advance notice.

HI 93713 is warranted for two years against defects in

workmanship and materials when used for its intended purpose and

maintained according to instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed

maintenance are not covered.
If service is required, contact the dealer from whom you purchased the

instrument. If under warranty, report the model number, date of purchase,

serial number and the nature of the failure. If the repair is not covered

by the warranty, you will be notified of the charges incurred. If the

instrument is to be returned to Hanna Instruments, first obtain a Returned

Goods Authorization Number from the Customer Service department

and then send it with shipment costs prepaid. When shipping any

instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card

within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.

Dear Customer,
Thank you for choosing a Hanna product. This manual will

provide you with the necessary information for the correct

operation of the meter. Please read it carefully before using

the meter. If you need additional technical information, do

not hesitate to e-mail us at [email protected].
This instrument is in compliance with directives.

Remove the instrument from the packing material and

examine it carefully to make sure that no damage has

occurred during shipment. If there is any damage, notify

your Dealer.
Each Ion Specific Meter is supplied complete with

• 9V Battery

• Two Sample Cuvets and Caps

• One Transport Cap

Note: Conserve all packing material until the instrument

has been observed to function correctly. Any defective

item must be returned in its original packing.

The HI 93713 meter measures phosphate (PO

4

3–

) content in

water, wastewater and seawater in the 0.00 to 2.50 mg/L
(ppm) range.
The meter uses an exclusive positive-locking system to ensure

that the cuvet is in the same place every time it is placed

into the measurement cell.
The reagents are in powder form and are supplied in

packets. The amount of reagent is precisely dosed to ensure

maximum repeatability.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature that will turn the

instrument off after 10 minutes of non-use.

SPECIFICATIONS

Range

0.00 to 2.50 mg/L

Resolution

0.01 mg/L

Accuracy

±0.04 mg/L ±4% of reading

Typical EMC

±0.01 mg/L

Deviation
Light Source

Light Emitting Diode @ 890 nm

Method

Adaptation of the ascorbic acid method.

The reaction between phosphate and

the reagent causes a blue tint in the

sample

Light Detector

Silicon Photocell

Environment

0 to 50°C (32 to 122°F);

max 95% RH non-condensing

Battery Type/Life 1 x 9 volt/40 hours

Auto-Shut off

After 10' of non-use

Dimensions

80 x 83 x 46 mm (7.1 x 3.3 x 1.8")

Weight

290 g (10 oz.)

REQUIRED REAGENTS

Code

Description

Quantity

HI 93713-0

Powder reagent

1 packet

REAGENT SETS

HI 93713-01 Reagents for 100 tests
HI 93713-03 Reagents for 300 tests

This indicates that the meter is in a
ready state and zeroing can be per-
formed.
Sampling in Progress. This prompt ap-
pears each time the meter is performing
a measurement.
This indicates that the meter is in a
zeroed state and measurement can be
performed.
A zero reading was not taken. Insert a
sample before adding reagent and press
ZERO.
Under range. A blinking "0.00" indicates
that the sample absorbs less light than
the zero reference. Check the procedure
and make sure you use the same cuvet
for reference (zero) and measurement.
Over range. A flashing value higher than
the maximum concentration readable (see
specifications) indicates that the sample
absorbs too much light, meaning that
the concentration is too high. Dilute the
sample.
Light over range. The cuvet is not in-
serted correctly and an excess ambient
light is reaching the detector. If the cover
is properly installed, then contact your
dealer or the nearest Hanna Customer
Service Center.
Light under range. The zero sample is
too dark for proper zeroing. If this is not
the case, contact your dealer or the
nearest Hanna Customer Service Center.
The "V" indicates that the battery volt-
age is getting low and the battery needs
to be replaced.
This indicates that the battery is dead
and must be replaced.
Note: once this indication is displayed,
the meter will lockup. Change the bat-
tery to restart.

V