Hanna Instruments HI 83221 User Manual

C 221 honey color analyzer

Advertising
background image

Instruction Manual

C 221

Honey Color Analyzer

This Instrument is in

Compliance with the CE Directives

Please examine this product carefully. Make sure that the
instrument is not damaged. If any damage occurred during
shipment, please notify your Dealer.
Each

C 221 Honey Color Analyzer is supplied complete with:

• Five Sample Cuvets

• 12 VDC Transformer

• One Light Shield Cap

(HI 710005 or HI 710006)

• One support for cuvets

• 30 mL Glycerol (1 bottle)

• Instruction Manual

• Two 9V Batteries

Note: save all packing material until you are sure that the

instrument works correctly. Any defective item must
be returned in its original packing.

Dear Customer,
Thank you for choosing a Hanna product. This manual will provide you
with the necessary information for the correct use of the instrument.
Please read it carefully before using the analyzer. If you need additional
technical information, do not hesitate to e-mail us at
[email protected] or call 1-800-426-6287.
This instrument is in compliance with

directives.

Preliminary Examination

General Description

The

C 221 portable microprocessor analyzer measures the

percent light transmittance of honey compared to analytical
reagent grade glycerol. The transmittance value allows
identification of the honey Pfund grade. The instrument
directly displays the measurement result expressed in mm
Pfund.
Measurements are made using matched square optical
cuvets having a 10 mm light path.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature that will turn the
instrument off after 10 minutes of non-use.

SPECIFICATIONS

Range

0 to 150 mm Pfund

Resolution

1 mm Pfund

Precision

±2 mm Pfund @ 80 mm Pfund

Typical EMC Dev. 1 mm Pfund
Light Source

Tungsten lamp with narrow band interference
filters @ 420 nm and 525 nm.

Method

Direct Measurement

Light Detector

Silicon Photocell

Environment

0 to 50°C (32 to 122°F);
max 90% RH non-condensing

Power supply

2 x 9V batteries / 12 to 20 VDC through voltage
adapter

Auto-Shut off

After 10' of non-use

Dimensions

230 x 165 x 70 mm (9.0 x 6.5 x 2.8")

Weight

640 g (22.6 oz.)

REQUIRED STANDARD

Description

Quantity/test

Glycerol

4 mL

Warranty

C 221 is warranted for two years against defects in workmanship and
materials when used for its intended purpose and maintained according
to the instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact your dealer. If under warranty, report the
model number, date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will be notified
of the charges incurred.
If the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization Number from the Customer Service
department and then send it with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete
protection.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.

Hanna Instruments reserves the right to modify the design, construction

and appearance of its products without advance notice.

FRONT PANEL

1) Cuvet Holder
2) Dual Level Liquid Crystal Display (LCD)
3) READ key, to perform measurement
4) CAL key, to calibrate the meter prior to measurement

5) ON/OFF key, to turn the meter on and off

REAR PANEL

1) Power Supply 12 VDC 2.5 Watt
2) RS 232 Socket
3) Batteries Compartment

Sampling in progress. This flashing
prompt appears each time the meter is
performing a measurement.

The microprocessor is adjusting the light
level, indicated by a scrolling "SIP".

This indicates that the meter has been
calibrated and measurement can be
performed.

The blinking "LOBAT" indicates that the
battery voltage is getting low and the
batteries need to be replaced.

This indicates that the meter is in a ready
state and zeroing can be performed.

This indicates that the batteries are dead
and must be replaced.

Light over range. The cuvet is not inserted
correctly and an excess ambient light is
reaching the detector. If the cap is properly
installed, then contact your dealer or the
nearest Hanna Customer Service Center.

This indicates that the meter has lost its
configuration. Contact your dealer or the
nearest Hanna Customer Service Center.

The lamp is not working properly. Contact
your dealer or the nearest Hanna Customer
Service Center.

The lamp is not working properly. Contact
your dealer or the nearest Hanna Customer
Service Center.

ERROR MESSAGES
a) on zero reading:

This indicates that the zeroing procedure
failed due to a low signal-to-noise ratio. In
this case press CAL again.

Honey color varies naturally in a wide range of tonalities,
ranging from light yellow to amber, dark amber and black in
extreme cases; sometimes green or red hues may also occur.
Color of untreated honey depends on botanical origin: for this
reason color is very important for definition and commercial
classification of monofloral honeys. Honey darkens with ageing,
and other changes in color may result from beekeeper’s
interventions and from the different ways of conservation (e.g.:
use of old honeycombs, contact with metals, high temperatures,
exposition to light, etc.).
The primary characteristic for commercial honey classification is
color. Color classes are expressed in millimeters (mm) Pfund
grades, compared to an analytical grade Glycerol Standard
Reference.
Table 1 reports the USDA classification for honey samples and
the related mm Pfund values.
Table 2 shows the color of different monofloral honeys: data are
obtained from a statistical set of honey samples. The table
reports for each type of honey: average value of color, standard
deviation, and the minimum and maximum values measured.

w w w . h a n n a i n s t . c o m

Significance and Use

Specifications

Guide to Display Codes

The instrument cannot adjust the light
level. Please check that the sample does not
contain any debris.

Advertising