Heath Consultants Sure-Lock Utility Pro User Manual

Page 29

Advertising
background image

26

(Correct - Grounding attachment allows signal

(Correct. - The coupler clamp jaws are closed
around the conductor. The conductor is
energized)

(Incorrect - Terminated end (open circuit). The

(Incorrect - The coupler clamp jaws are
clamped to the conductor. The conductor is not
energized)

Figure 2-8

Figure 2-9

Using the Receiver
A correct understanding of the transmitter’s use is important to assure proper
signals at the receiver’s location. As a highly developed computerized instru-
ment, the Sure-Lock is capable of providing remarkable accuracy in a wide

1. ONCE THE CONDUCTOR IS PROPERLY ENERGIZED:

a. Turn the receiver on and select the appropriate frequency matching that

on the transmitter.

operational time. The battery test indication will read in 20% incre-
ments of available voltage in the batteries.

c. The operator should slowly sweep the receiver as it searches for the

conductor. The operator will notice the following visual and audio indi-
cations on the display and from the built-in speaker:

LOCK indicator will appear on the display. This assures that the