Distributed by: technical specifications chart, Dls-90 – IOTA DLS-90 User Manual

Page 4

Advertising
background image

Distributed By:

TECHNICAL SPECIFICATIONS CHART

68357-000 REV 091613

IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com

13.6V (DC)

+ or - .7%

15 Amps

>13.4V (DC)

200 Watts

<50 mV rms

108 - 132 AC

47-63

3.7 Amps

>80%

30 Amps

Yes

>100%

100 mV rms

<1%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

9.7

″ x 6.7″ x 3.4″

4.5 lbs

DC Output Voltage (No Load) approx.

Output Voltage Tolerance (No Load)

Output Amperage, Max Continuous

Output Voltage (Full Load) approx.

Maximum Power Output, Continuous

Ripple and Noise

Input Voltage Range

Input Voltage Frequency

Maximum AC Current (@108Vac)

Typical Efficiency

Max Inrush Current, Single Cycle

Short Circuit Protection

Overload Protection

Line Regulation

Load Regulation

Fan Control

Thermal Protection

Working Temperature Range

Storage Temperature

Withstand Voltage (VDC)

Approximate Dimensions

Weight

13.6V (DC)

+ or - .7%

30 Amps

>13.4V (DC)

400 Watts

<50 mV rms

108 - 132 AC

47-63

7.3 Amps

>80%

30 Amps

Yes

>100%

100 mV rms

<1%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

9.7

″ x 6.7″ x 3.4″

4.5 lbs

13.6V (DC)

+ or - .7%

45 Amps

>13.4V (DC)

600 Watts

<50 mV rms

108 - 132 AC

47-63

11 Amps

>80%

30 Amps

Yes

>100%

100 mV rms

<1.5%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

9.7

″ x 6.7″ x 3.4″

5.0 lbs

13.6V (DC)

+ or - .7%

55 Amps

>13.4V (DC)

750 Watts

<50 mV rms

108 - 132 AC

47-63

13.4 Amps

>80%

30 Amps

Yes

>100%

100 mV rms

<1.5%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

9.7

″ x 6.7″ x 3.4″

5.0 lbs

13.6V (DC)

+ or - .7%

75 Amps

>13.4V (DC)

1000 Watts

<100 mV rms

108 - 132 AC

47-63

18.2 Amps

>80%

40 Amps

Yes

>100%

100 mV rms

<1.5%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

13

″ x 6.5″ x 3.4″

7.8 lbs

DLS-15

DLS-30

DLS-45

DLS-55

DLS-75

**Requires 30A breaker

SERIES m

SERIES m

SERIES m

DLS-90 *

13.6V (DC)

+ or - .7%

90 Amps

>13.4V (DC)

1200 Watts

<150 mV rms

108 - 132 AC

47-63

21.8 Amps**

>80%

40 Amps

Yes

>100%

100 mV rms

<1.5%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

13

″ x 6.5″ x 3.4″

7.8 lbs

SERIES m

RATINGS AND SPECIFICATIONS

Primary to Chassis/Primary to Secondary/Secondary to Chassis

*Unit is not UL Listed

Advertising