Konig Electronic Wireless alarm system User Manual

Page 7

Advertising
background image

ENGLISH

7

The slightest vibration will trigger the sensor. It’s not recommended to

install the vibrate sensor on windows near to doors. Slamming doors will

trigger the sensor.

4. Insert, according the diagram inside the battery compartment, (backside)

the batteries for PIR sensor (3x AAA). The PIR sensor needs to warm up for

30~40 seconds for first use. In this period it cannot detect motion. Install

the PIR sensor at a height of 1~1.5 m for best performance. Do not install

the PIR sensor into direct sunlight, facing towards windows, objects that

move easily and heat or cold source.

5. Remove the transparent front cover of the alarm unit to write down the

position of the sensors corresponding with the numbered LED. (e.g. sensor

1=front door, 2=kitchen window, etc.).

6. Install the alarm unit to a location. The distance between the alarm unit and

the most far away sensor may not exceed 60 m (open area)*.

7. Switch on the alarm unit to ALARM or CHIME function. If switched to

CHIME, the alarm unit will sound like a door bell when a door or window is

opened. Switched to ALARM generates a 100 dB loud siren. When the alarm

unit is switched on, the alarm is not armed (active) yet. Push the ON button

on the remote control to arm the alarm and OFF to disarm. The delay time

for entering and leaving the protected area is between 20~25 seconds.

8. It’s recommended to test the alarm system for correct operation with first

use and every 3 months.

Procedure:

a) Switch on the alarm unit to ALARM or CHIME (for testing recommend).

b) Push the ON button on the remote control to arm the alarm.

c) Wait for 20~25 seconds (delay time).

d) For testing door/window sensor, open every door or window one

by one and check if the corresponding LED lights up and the CHIME

sounds.

e) For testing PIR sensor, move around the PIR sensor and check if the

corresponding LED lights up and the CHIME sounds. Note: the LED

indicator on the PIR sensor lights up also.

f) For testing vibrate sensor, hit carefully on the window and check if the

corresponding LED lights up and the CHIME sounds.

g) Disarm the alarm if everything operates correct.

h) The alarm system is ready to use.

Advertising