Battery indicator

The battery indicator flashes every 45 seconds to show that the smoke alarm is

working properly. When the battery indicator flashes and gives a short beeping

sound, it indicates that the battery has a low capacity and should be replaced

immediately.

3. LEARN button

Follow the next steps to set the MAIN smoke alarm and ASSISTANT smoke

alarm(s) to create a smoke alarm system with 2 or more SAS‑SA200/2002’s.

1. Press the LEARN button two times. The LEARN indicator turns from red to

green. This smoke alarm will be the MAIN smoke alarm. Ensure the LEARN

indicator is green before proceeding.

2. Press the LEARN button of the ASSISTANT smoke alarm(s) once. The ALARM

indicator(s) turns on red. Ensure the ALARM indicator(s) are red before

proceeding.

3. Press the TEST button of the MAIN smoke alarm for several seconds in order

to send out the learn signal to the ASSISTANT smoke alarm(s). The ALARM

indicator flashes and the smoke alarm sounds. The ASSISTANT smoke

alarm(s) receive the signal and sounds.

4. Press the TEST button on each ASSISTANT smoke alarm(s) for several

seconds in order to send out the learn signal to the MAIN smoke alarm. The

MAIN smoke alarm receives the signal and sounds.

Note: the number of smoke alarms is unlimited. The maximum range between

2 smoke alarms to communicate with each other is 40 metres.

4. LEARN indicator

5. Mounting plate and holes

Use the supplied screws and plugs to mount the mounting plate to the ceiling.

6. Remove the mounting place

Turn the mounting plate of the smoke

alarm counter clockwise to get access to

the battery compartment of the smoke

alarm.