LA Audio G400 User Manual

Page 10

Advertising
background image

Page 10

4.0 INSTALLATION

4.1

INSPECTION AND UNPACKING

The G400 has been carefully packed at our factory in a carton designed to

withstand handling in transit. Should the unit appear to have been damaged in

transit, notify your dealer immediately and do not discard any of the packing. The

carton should contain -

The G400

Power cord - country specific, please check

Operator Manual (this book)

4.2

OPERATING ENVIRONMENT

The G400 is designed to operate between 0°C and 40°C (32-112°F) with relative

humidity no more than 80%. Should the units be installed in an equipment rack,

ensure that the ambient temperature conforms to these levels.

4.3

CE STANDARDS AND THE LOW VOLTAGE DIRECTIVE (LVD)

The G400 has been designed to comply with the latest Electromagnetic

Compatibility (EMC) regulations. However we recommend you do not operate the

unit close to strong emitters of electromagnetic radiation such as power

transformers, motors, mobile telephones or radio transmitters.

The unit should only be connected to a power supply of the type described in 4.4

POWER REQUIREMENTS or as marked on the unit. Disconnect the mains

supply before removing any cover.

4.4

POWER REQUIREMENTS

The G400 is factory configured for either 230V 50Hz ac or 115V 60Hz ac mains

operation. Please refer to the following diagram which shows the transformer

connections for 230V and 115V –

The rating of the rear panel fuse is shown on the cover -

230V

115V

T125mA

T250mA

All are slow blow type