3

Secure using 5mm (3/16") bolts (not supplied)

through the 4 mounting feet

TAKE TIME TO LOCATE THE BEST POSITION

If necessary, power the Receiver and move it around
the vehicle until the required performance is achieved.
Operate the Transmitter and observe the Receiver
internal LED’s.

Mount as HIGH as possible
AVOID surfaces with HEAVY VIBRATION
AVOID
DIRECT SPRAY from wheels
In a HOT CLIMATE fit in a SHADED position
Cable gland should face DOWN or BACK

Receiver 9206RX and 9306RX shown,
Waterproof to IP67, complete with 3 metres (10 ft) cables

CAUTION

MOUNT RECEIVER

2

or Disconnect Battery

IDENTIFY POWER

CONNECTION POINT

AND ISOLATE SUPPLY

Fuse

Remove fuse

Vehicle batteries contain gasses
which are flammable and explosive.
Wear eye protection and do not lean
over battery while disconnecting. Do
not wear metal jewellery.

!

WARNING

POSITIVE

NEGATIVE

92106RX.01E

7 core cable.
These are
Power Outputs

Transmitter Function I.D.

2 core cable.
These are
Power Inputs

1.

The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps

through one output or 5 Amps each through 3 outputs.

2.

Master Output. This can be configured to Continuous or Parallel operation, see overleaf for

details.

3.

If Receiver outputs are connected in parallel with an external switching device (wired remote)

the Receiver will instantly switch off when the wired remote is operated

4.

Lodar Receivers

have an isolation switch for safety, to allow for registering a

MUST

replacement Transmitter.

5.

Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of

inactivity. This can be altered, ask your dealer.

1

!

BEFORE YOU START

!

F1

F2

F3

F4

F5

F6

Wiring Instructions for 92 Series & 93 Series 6 Function Receivers

CONNECT

WIRES

4

5

or re-connect Battery

ACTIVATE THE

RECEIVER SUPPLY

Fuse

Replace fuse

Press the Transmitter

button

RESET

to activate the system, and carefully
test each function for correct operation.

7

TEST

6

CONNECT TRANSMITTER BATTERY

Batteries generally have to be

disconnected when shipping.

BLACK

RED

GREEN

YELLOW

BROWN

BLUE

WHITE

Output Function 1

Output Function 2

Output Function 3

Output Function 4

Output Function Master

7 Core wire used for:-

Wire Colour

Make notes about the connections made in the boxes

What is the MASTER Output for ?
It is used to operate the pump of an electro-hydraulic
power pack or maybe a clutch pump. It can also be
used for powering a dump valve, master valve etc.
It can be configured to work continuously, that is ON
when SET is pressed and OFF when STOP is
pressed; or in parallel with any output, that is, it is
active only a function is operated. If it is needed with
certain functions only, this can easily be configured.

Output Function 5

Output Function 6

12/24 Volts DC Nominal
Positive Supply

RED

Negative

BLACK

2 Core wire used for:-

Wire Colour

Shown with optional Keypad

Advertising
Table of contents