9

Rev 1.13

Basic Setup

− Step By Step

The remote control setup sequence for common configurations is described below.

Connect video cables and power. Turn all required components on.

Set the output type. Use RGBHV (default) if display has an RGBHV input. Examples:

YP

R

P

B

trilevel:

MENU 1 1 OK

Component with embedded trilevel sync

YP

R

P

B

bilevel:

MENU 1 1 OK Component with embedded bilevel sync

RGB H

V

:

MENU 1 2 OK

RGB with discrete H

and V

sync (default)

RGB S

:

MENU 1 3 OK

RGB with discrete composite

sync

(default)
RGsB:

MENU 1 4 OK RGB with embedded bilevel sync

Set the output resolution. For a fixed pixel device use the maximum resolution it

accepts, not its native resolution. This will improve the picture unless there is a major
design flaw in the fixed pixel display. The commands are as follows:

480p:

MENU

2

1

540p:

MENU

2

2

600p:

MENU

2

3

720p:

MENU

2

4

768p:

MENU

2

5

840p:

MENU

2

6

1080p:

MENU

2

7

1080i:

MENU

2

8

Other:

MENU

3

value

OK

, where

value

is the resolution (e.g.

9

,

0

,

0

)

Set the vertical refresh rate (default = 59.94 Hz). For NTSC, use the default. For PAL,

using 50.00 Hz is optimal, but higher rates can be used to reduce flicker. Press

MENU 4 value OK ” where “value ” is the vertical refresh rate in hundredths. For

example a vertical refresh rate of 59.94 is entered as

MENU 4

5 9 9 4

OK.

Set the output aspect ratio. Press “

MENU 6 value OK ” where “value ” is the desired

screen aspect ratio in hundredths (16:9 is

MENU 6 1 7 8

, 4:3 is

MENU 6 1 3 3

)

For

MENU

commands press the

MENU

button, use arrow keys to highlight the next

item in the list and press the

OK

button. An “

”denotes levels in the menu hierarchy.

Play a DVD calibration disc and select it as the input source. Typically either AVIA™

or Digital Video Essentials™ calibration DVDs are used.

Display one of the test images with “overscan” markers. On AVIA one such test pattern

is the 200 TVL chart in the Advanced AVIA section. Select the appropriate input
aspect ratio so the test pattern is full-screen (e.g. 16:9 for a 16:9 screen aspect ratio).

Adjust output size and position to minimize the amount of overscan. In other words, try

to get the entire active image on-screen. If the display has output size and position, use
it rather than the Lumagen controls. Otherwise use the following Lumagen commands:
For sizing:

MENU

OUT

RES

SIZE

[ , , , ],

OK

For positioning:

MENU

OUT

RES

POS

[ , , , ],

OK

Adjust the input size and position using the Lumagen controls. When the Lumagen

input size controls are selected, the corner of the image being adjusted is moved toward
the center of the screen to simplify accurate calibration. First adjust the top-left of the
image so that all active pixels are on-screen. Then adjust the bottom-right.
For top-left:

MENU

IN

ADJ

SIZE

TOPL

[ , , , ],

OK

For bottom-right:

MENU

IN

ADJ

SIZE

BTMR

[ , , , ],

OK