LW Measurements TSB 1416 Planar Bench Scale User Manual

Page 4

Advertising
background image


Parameter setting:







Open the lower cover ,then press <CAL> key on the main board and it will
show “------”, press < Gross/Net > to enter menu.

Format of parameter: - x - - n n ("x" means the order of parameter; "n n"

means specific parameter.

Operation: <Gross/Net> : change X in circle

<TARE>:Displayed value increase 1 by pressing the key every time .

<PRINT>: Displayed value minus 1 by pressing the key every time.

Setup Menu Chart:

-5-

Setup Menu Description:

6

6

CODE NAME

DESCRIPTION

CODE/

VALUE

0

LB/KG

units

conversati

on setting

nn=00: Power-on unit is lb and

units conversation is not available.

nn=0: Power-on unit is lb and units

conversation is available.

nn=02: Power-on unit is kg and

units conversation is available.

nn= other value, same to nn=02.

00,

0,

02,

nn

1

responding

rate

for

sampling

nn=00:rate=6.25Hz ( the slowest)

nn=01:rate=7.5Hz

nn=02:rate=12.5Hz

nn=03:rate=15Hz

nn=04:rate=25Hz

nn=05:rate=30Hz

nn=06:rate=50Hz

nn=07:rate=60Hz (the fastest)

nn= other value ,same to nn=00.

00,

01,

02,

03,

04,

05,

06,

07,

nn

2

LB division

displayed

Minimum difference between two

weighing readings.

01

,02…

nn

3

Overload

limit

nn=00:fixed 10000 point

nn=99:No overweight

nn=others:overweight

range=101*nn

00,

30

99.

nn

4

unstable

range

(a

“d” as a

unit)

The OMT LED light out and the

weighing operation is enable while

motive reading is not exceeded

the limit of this selection.

01

,02…

nn

Advertising