Control board settings, Dip switches – Mighty Mule FM502 Green Board User Manual

Page 28

Advertising
background image

24

1

ON

2 3 4 5 6 7

ON

OFF

1 2 3 4 5 6 7

DIP#6 DIP#7 Delay Time for Auto-Close
ON

ON

15 seconds

ON

OFF

30 seconds

OFF

ON

60 seconds

OFF* OFF* 120 seconds (factory preset)

DIP#5
ON

D1 mode, constant pressure to operate gate.

OFF* B2 mode, momentary contact to operate gate.

DIP#4
ON

Push-to-open operation.

OFF* Pull-to-open operation.

DIP#3
ON

Auto-close enabled.

OFF* Auto-close disabled.

DIP#2
ON*

Buzzer warning enabled.

OFF

Buzzer warning disabled

DIP#1
ON*

Soft start enabled.

OFF

Soft start disabled.

* Factory preset.

CONTROL BOARD SETTINGS

DIP Switches

Main DIP Switch Settings (MODES)

DIP Switch #1 - Soft Start/Stop

The Soft Start/Stop feature slowly starts the gate as
it begins to open and slows the gate as it comes to
the closed position. This saves wear and tear on the
gate and gate opener system.

DIP Switch #2 - Warning Buzzer

The Warning Buzzer alerts you when the gate
opener is beginning to either open or close the gate.
It sounds for the fi rst 2 seconds in each direction.
It also sounds a warning when the gate obstructs
two times in one cycle. Switching this to OFF
only disables the open and close warning not the
obstruction warning.

DIP Switch #3 - Auto-Close

With the Auto-Close switch in the OFF position
the gate will remain open until it receives another
signal from an activation device such as a
transmitter, keypad, or push button control. With
the Auto-Close switch in the ON position the gate
opener will automatically close the gate, if the gate
is in it's open limit position. The time the gate will
remain open is determined using DIP Switches #6
and #7.

DIP Switch #4 - Push/Pull-to-Open

If your gate opens into the property the DIP Switch
is set to OFF (factory). If your gate opens out from
the property the DIP Switch must be set to the ON
position. NOTE: if you have a Push-to-Open gate
application you will need a Push-to-Open bracket
(see Push-to-Open Instructions on page 30).

DIP Switch #5 - B2/D1 Mode

This DIP Switch must remain in the OFF position
unless the gate opener is going to be used by a
guard or gate attendant, who can only open the gate
when constant pressure is applied to a push button
control device.

DIP Switches #6 and #7

The combination of these two switches determines
the amount of time the gate will remain open when
DIP Switch #3 is set in the ON position.

NOTE:

Leave DIP Switch #3 in the OFF position untill installation is complete, to prevent gate from

automatically closing during installation.

IMPORTANT CONTROL BOARD SETTINGS:

CONTROL BOARD DIP SWITCH #1 is factory
preset in the ON position and MUST remain in the
ON position. Changing this setting can damage
your gate, gate opener and
possibly void your warranty!