Mighty Mule R4222 User Manual

Page 10

Advertising
background image

Symptom

Possible Cause

Remedy

Transmitter LED does not light.

Improper voltage supplied.

Check the power supply and wiring.

Receiver LEDs do not light.

Improper voltage supplied.

Check the power supply and wiring.

Alarm LED does not light,
even when beams are blocked.

1. Beams reflect to the receiver
by other objects.
2. Both beams are not blocked
simultaneously.
3. Beam interruption time is too short.

1. Remove the reflecting object or change
optical axis direction.
2. Block both beams.
3. Increase beam interruption time
adjustment.

When beams are blocked, receiver LED
lights are ON, but not alarm.

1. Wiring is short circuited.
2. Wiring connection is not good.

Check wiring and connection spot.

The alarm indication lamp of receiver is
always on.

1. Optical axis is not properly adjusted.
2. There are obstructions between the
transmitter and the receiver.
3. The outer covers are dirty.

1. Adjust the optical axis.
2. Remove the obstructions.
3. Clean with window cleaner and a
soft cloth.

Intermittent Alarm (detection)

*If you’re experiencing false detections
then increase the time adjustment by 1
increment at a time until the photo beam
functions as desired.

1. Bad wiring.
2. Fluctuating power supply / voltage.
3. Intermittent blockage between the
transmitter and the receiver.
4. The receiver or transmitter is unstable.
5. Blocked by other moving objects.
6. Beam interruption time out of adjustment.

1. Check wiring.
2. Check the power supply.
3. Remove the obstruction or relocate.
4. Fix the mounting.
5. Adjust the optical axis.
6. Adjust interruption time or change
installation position.

MODEL R4222

Detection Method

Infrared photoelectric

Range

Outdoor

98.4 ft (30m)

Indoor

295.2 ft (90m)

Beam Characteristics

Pulsed infrared dual beams

Response Time

50~700msec (selectable)

Power Input

DC12.5~24V / AC11~18V

Current Consumption

40mA max

Output Pulse Duration

2Sec (±1)nominal

Alarm Output

Form B relay (AC/DC 30V 0.5A max)

Tamper Switch

N.O. contact is open when cover is removed (transmitter and reciever)

Operating Temperature

-13˚F (-25˚C)~131˚F (55˚C)

Environment Humidity

95% max

Alignment Angle

20˚±10˚ vertical, ±90˚ horizontal

Mounting

Wall or pole

Weight

.66lbs (300g) Both transmitter and receiver

Appearance

PC Resin (Black)

Condition

Indication

Transmitter

Transmitting

POWER LED is ON

Receiver

Beam Not Blocked

GOOD and LEVEL LEDs are ON

Beam Blocked

ALARM LED is ON

VERIFY CORRECT OPERATION

TROUBLESHOOTING

SPECIFICATIONS

After installation, confirm
correct operation by suitable
walking tests. Refer to the
appropriate LED indicators
during the walking test and
ensure the gate opener
operates in the correct manner.

For optimal

efficiency, wipe
the outer cover

frequently with a

soft, damp cloth.

Not compatible

with Solar Panels.

For online Technical Support visit the Online Troubleshooter Wizard 24 hrs/day 7 days/week at

http://support.gtoinc.com/support/troubleshooter.aspx and open a Tech Ticket

Technical Support Hours: MON - FRI 8:00AM - 7:00PM (ET) (800) 543-1236

Advertising