Step 27

Plug the transformer into the electrical outlet.
(Use of a surge protector with the transformer is strongly
recommended.)

HINT: Keep a few mothballs in the control box to
discourage insects from entering it and damaging the
control board.

Step 28

Turn control box ON.

Step 26

Strip

1

/

2

" of insulation from the ends of the low

voltage wire. Attach these stripped ends to the
transformer terminals; red wire to RED,
black wire
to BLK.

A dab of household petroleum jelly on each terminal
will help prevent corrosion.

We suggest crimping a spade tongue terminal (not
provided
) to the end of each wire before attaching it
to the transformer.

Make sure the exposed wires do not touch each
other!

SURGE PROTECTOR

Transformer

Spade Tongue Terminal
(not provided)