Keying Indication Summary:

Keying Error Alert Indication

Keying accepted confirmation Indication

Master Code Setting

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

STATUS light: rapid flashing

STATUS light: no light, no flashing

Permanent Entry Code

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

STATUS light: rapid flashing

STATUS light: no light, no flashing

Temporary Entry Code

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

Setting

STATUS light: rapid flashing

STATUS light: no light, no flashing

Entry Code Matching

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

(after non-matching 20 keying)

STATUS light: rapid flashing

STATUS light: no light, no flashing

Normal Keypad Operation:

• If the user enters a 4-digit code that is matched to one of

the 25 stored codes. The STATUS light should blink and the
beeper should beep twice to confirm that a matched code is
entered. The lock is pulled for 3 sec (factory default).

• No more than 20 key presses are allowed to obtain the 4-digit

entry code.

Example:
1234 is one of the codes stored in one of the memory location.

The user can enter ‘x1234’ or ‘xxxxxxxxxxxxxxxx1234’ and the
gate should be activated (x is any key). If more than 20 key
presses is entered without matching one of the codes then the
unit’s STATUS light should be flashing rapidly and no entry will
be accepted for the next 40 seconds. The user must not enter
any code for at least 40 seconds before the unit returns to nor-
mal operation; otherwise it remains in this ‘lock-down’ mode.

The contents of all material available on this installation manual are copyrighted by Gates That Open, LLC (“GTO”), unless otherwise indicated. All rights are reserved by

GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of

GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law.

GTO®, GTO/PRO®, Mighty Mule® are registered trademarks of Gates That Open, LLC, Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive

property ofGates That Open, LLC (“GTO”). All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.

Delete ALL Entry Codes:

• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM

button.

• Enter 0, 7 then press and release PROGRAM button.
• Beeper beeps 3 times to confirm that the All Entry Codes are

deleted.

Example: Key press sequence to delete all entry codes from
memory. (for example if 3121 is the Master Code)

The round black dot is the ‘PROGRAM’ button.

Program Lock-Hold Time:

• Press & release PROGRAM button.
• Enter the Master Code then press & release the PROGRAM

button.

• Enter ‘0’, ‘4’ then press & release the PROGRAM button.
• Enter any number between 1-9 and press & release the PRO-

GRAM button. This number is the number of seconds the lock
will hold (unlock) for once it is activated.

Example: Key press sequence to program the lock to hold for
5 seconds (1234 is the Master Code)

3 1 2 1 0 7

1 2 3 4 0 4 5

Low Battery Indication Summary:

Low Battery Indicator

Beeps twice when any key is pressed.

Battery OK

Beeps once when any key is pressed.

Advertising