Installation

Important: To ensure that this

equipment reaches you in first class
condition, protective coatings have
been used. Flush the equipment
through with a suitable solvent
before use.
1. Attach air hose to connector (13).

Recommended hose size 8 mm
bore. The air supply should be
filtered and regulated.

2. Attach the Cup Lid assembly (27)

to the Fluid Inlet connector (17).

3. Position the Yoke at right angles

to the Gun with the Cam lever to
the front (see picture). Make sure
the vent hole in the lid is
positioned under the Yoke and
the hole in the diaphragm is 180°
to the Lid vent hole.

E

E

Operation

1. M i x c o a t i n g m a t e r i a l t o

manufacturers instructions.

2. Fill the cup with the required

amount of material. Fill to no more
than 25mm(1“) from the top of the
cup. DO NOT OVERFILL.

3. Attach Cup to the Lid assembly.
4. Turn needle adjusting screw (10)

on the spraygun clockwise to
prevent movement.

5. Turn pattern valve (5) counter-

clockwise to fully open

6. Adjust inlet air pressure to give

3.5 bar (50psi) at the gun inlet
with the gun triggered. (pressure
gauge attachment shown under
Accessories is recommended for
this).

7. Turn needle adjusting screw

counter clockwise until first thread
shows.

8. Test spray. If the finish is too dry

reduce airflow by reducing inlet
pressure. If finish is too wet
reduce fluid flow by turning needle
s c r e w ( 1 0 ) c l o ck w i s e . I f
atomisation is too coarse,
increase inlet air pressure. If too
fine reduce inlet pressure.

9. The pattern size can be reduced

by turning adjusting valve (5)
clockwise.

10. Hold gun perpendicular to surface

being sprayed. Arcing or tilting
may result in uneven coating.

11. The recommended spray distance

is 150-200 mm (6”-8”).

12. Spray edges first. Overlap each

stroke a minimum of 50%. Move
gun at a constant speed.

13.

Always turn off air supply and
relieve pressure when gun is not
in use.

Air Flow Valve (14)

1. If the airflow valve (14) is fitted

this can be used to reduce the
inlet pressure through the gun.
Screw the Adjusting Knob in to
reduce pressure.

Advertising