OPTI-UPS TS1000B User Manual

OPTI-UPS Power suppliers

Advertising
background image



www.opti-ups.com

Placement

This UPS is intended for indoor use
only;

its internal components are not

sealed

from the environment.

Please install it in a protected
environment away from excessive heat
or excessive moisture.

Connecting your equipment to the UPS

For all UPS models except the version with IEC outlets: connect the power cord(s) of
your computer equipment to the output receptacle(s) of the UPS.

For UPS with IEC outlets, as shown in the illustration, use your computer power cord
to connect UPS to the wall socket. Use the power cord supplied with the UPS to
connect your PC to one of UPS outlets.

Turn on the UPS

To turn UPS on please press the power button for 3 seconds. Pressing the power
button shortly under normal mode will enable the self-test function. The silence
function can be enabled/disabled by shortly pressing the power button in backup
mode. In addition, the power button can be used as the master on/off switch for your
equipment by leaving your equipment connected to UPS and switched on. To turn off
the UPS, please press power button for about 3 seconds.

Front & Rear Panels




1.1 Power Button
1.2 RS-232 Port

*)

1.3 Phone/LAN Jack

*)

1.4 AC Input
1.5 UPS Outlets
1.6 AC Fuse

*)

TS-B models only

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This Manual contains important instructions that should be followed during installation and maintenance

of the UPS and batteries.

Intended for installation in a controlled environment.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the

required precautions. Keep unauthorized personnel away from batteries.

When replacing batteries, replace with the same number and type.

CAUTION -

Do not dispose of battery or batteries in a fire. The battery may explode."

CAUTION -

Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin

and eyes. It may be toxic.

CAUTION -

A battery can present a risk of electrical shock and high short circuit current. The

following precautions should be observed when working on batteries:

- Remove watches, rings, or other metal objects.

- Use tools with insulated handles.

- Wear rubber gloves and boots.

- Do not lay tools or metal parts on top of batteries.

- Disconnect charging source prior to connecting or disconnecting battery terminals.

No Load Shutdown Function

As a battery saving feature, the UPS will automatically turn off if none of the connected equipment
is operating while the UPS is in back-up mode. Once normal utility power returns, the unit will
re-start automatically. You can disable the “No Load Shutdown” function by pressing the power
button of your switched-off UPS until you hear two beeps.

Front panel LED (UPS status indicator)

AC Mode

When the LED is continuously lit and the buzzer is silent, the UPS is in
normal mode and providing power to your equipment. The UPS will
continue to filter electrical noise and provide surge protection.

Battery Mode

When the LED blinks every 2 seconds in time with the beeping sound, the
UPS is providing power from its battery.

Fault

When the LED is flashing rapidly and the beeping sound is continuous, it
indicates that the UPS is overloaded.

Warning

DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE
THEY TYPICALLY DRAW TOO MUCH POWER








Fuse replacement procedure

1. Use a slotted screwdriver to take out the fuse holder
2. Take out the busted fuse from the fuse holder
3. Use the screwdriver to push out the spare fuse from the holder
4. Put the spare fuse in the holder
5. Push the fuse holder back into the AC input socket
6. Follow the UPS turn on procedure

Fuse

Holder

Charging the UPS first

The battery is fully charged at the
factory. However, it is recommended
to charge the battery at least 8 (eight)
hours before using the UPS, since
energy loss may have occurred during
shipping or long duration storage. To
recharge the battery, simply leave the
UPS plugged into an AC outlet.