Maximum Recommended Distances Between Centers- Shorter Spans (width)
Under different ratios and loads for four sides clamped / framed flat glazing.

Structure

Thickness

Wind/snow

uniform loads

Distance between centers (shorter span) according to ratio a:b

Ratio 1:1

Ratio 1.5:1

Ratio > 1.5:1

mm

Kg/m²

psf

mm

Inch

mm

Inch

mm

Inch

Twin Wall

6

50

10

900

36

700

28

500

20

80

16

700

28

500

20

350

14

100

20

500

20

400

16

-

-

120

25

400

16

300

12

-

-

8

50

10

1150

45

900

36

600

24

80

16

1000

40

800

28

480

19

100

20

900

36

650

22

450

18

120

25

750

30

600

20

-

-

10

50

10

1250

50

1000

40

750

30

80

16

1200

47

900

30

550

22

100

20

110

43

800

24

500

20

120

25

950

37

700

21

450

18

Triple Wall

8

50

10

1200

47

950

38

650

26

80

16

1050

42

750

29

510

20

100

20

950

37

650

22

470

18

120

25

900

38

650

22

480

19

10

50

10

1275

51

1050

41

800

32

80

16

1225

49

900

32

600

24

100

20

1125

44

750

26

550

22

120

25

900

38

650

22

480

19

16

50

10

1500

59

1200

47

1100

43

80

16

1300

52

1100

43

1000

41

100

20

1200

47

1050

41

900

36

120

25

1100

43

950

37

850

33

X-Lite

16

50

10

1550

61

1250

49

1150

45

80

16

1350

53

1150

45

1050

41

100

20

1240

49

1080

42

950

37

120

25

1130

44

980

38

900

35

25

50

10

2100

83

1700

67

1400

55

80

16

1950

76

1600

63

1650

53

100

20

1800

70

1500

59

1300

51

120

25

1650

65

1400

55

1250

49

32

50

10

2100

83

1850

73

1500

59

80

16

2100

83

1700

67

1400

55

100

20

2000

78

1600

63

1350

53

120

25

1850

73

1500

59

1300

51

35

50

10

2100

83

1875

74

1525

60

80

16

2100

83

1725

68

1425

56

100

20

2025

79

1652

64

1375

54

120

25

1875

74

1525

60

1325

52

Notes:
1. SUNLITE 4mm twin-wall is not recommended for constructive applications and is therefor excluded.
2. Data in table according to load tests on typical multi-wall sheets and additional extrapolations.
3. Recommended spans are calculated on the basis of 1/20 maximum deflection (5%) of sheet’s width (In this case crosswise, perpendicular to the rib channels).
4. A SUNLITE glazing sheet may withstand even higher loads without buckling, however, excessive lateral shortening, created by higher deflection, may cause the
edges to slip out of their supports (pop-out).

Advertising