SUNTUF® Technical Guide

Profile: 107/27 (American 4.2)

©PALRAM Industries. All rights reserved.

Profile Drawing

Profile Dimensions

Profile

(mm)

Thickness

(mm)

Length

(m)

Overall width

(mm)

Cover Width

(mm)

Side-Lap

( % )

107 / 27

0.8-1.5

1.5 - 11.8

1070

963

10



Load / Span Data

Maximum Roof Span (mm)

1.0 mm

1.2 mm

1.5 mm

Load

(kg/m²)

Mid Field

End Field

Mid Field

End Field

Mid Field

End Field

75

1250 940 1300 975 1350 1010

100

1150 860 1200 900 1250 940

125

1050 790 1100 825 1150 860

150

950 710 1000 750 1050 790



ƒ The dimensions specified do not supersede the requirements of local construction codes.

ƒ The maximum purlin spans are based on continuous beam calculation model and practical testing.

The criterion for allowed deflections is L/20.

ƒ For single span application use the end field column.

ƒ The mentioned load refers to both wind and snow loads and intended for rooflights only.

ƒ Minimum recommended slope – 10%.

ƒ Maximum recommended panel length - 7.0 m.



Curved Roof

ƒ Minimum curving radius 6.0 m.