SUNTUF® 177 / 51 (5,6,waves)
Installation Guide

13/02/2006

1

Profile Dimensions

Profile

(mm)

Thickness

(mm)

Length

(m)

Width

(mm)

Effective

Width (mm)

Side-Lap

(%)

920 885 3.8

1100 1062 3.4

177 / 51

1.0 – 1.5

1.5 - 11.6

1100 885 19.5

(1100)

Load / Span Data

Maximum Roof Span (mm)

Load

(kg/m

2

)

1.0 mm

1.5 mm

50

1250 1500

80

1200 1400

110

1150 1300

The dimensions depicted do not supersede the requirements of local construction codes.

Purlins spans are based on the panel’s structural properties, sheet deflection, potential wind and

snow load, hail and other applicable factors according to construction practice, professional

expertise and previous field experience.

In vertical walls, the spans can be increased by 10%.

Minimum recommended slope for a new roof – 10%.

Maximum recommended sheet length – 7.0 m.

Safety

Do not step directly on the sheets - before,

during or after installation.

Work according to local safety regulations.

Use stepping ladder or crawling boards.

Positioning

The sheets must be laid on the roof against the primary direction of wind

and rain.

The SUNTUF sheet must be installed without any stresses. Do not pull, stretch or

force the sheets when the profiles are not perfectly matched.

Always install with the UV protected side facing out.