Mounting Instructions

Save these instructions

Page 4

11.40”

(28.9 cm)

Drill 1/4”

(6.5mm) hole

Drywall Anchor

Anchors are for dry-

wall where wall studs
are unavailable

1 1/4” screw

Fig. 1

Fig. 2

Fig. 3

Assembly View

Dowel

Base Mount

Frame

Paraclipse Fly Patrol

Contents:

Operation Manual.

One Sconce Assembly.

Drywall Anchor kit with Instructions.

One Frame Assembly with Power Cord.

One Cartridge.

One UV Quantum Lamp.

Unit location on wall - Fig. 1

Select a wall away from windows or competing
light source. For best results, mounting holes
should be located 66” (1.68 m) above the floor.

Mounting unit to wall - Fig. 2

1.

Mark two locations on the wall for your fasten-
ers that are 11.4” (28.9cm) apart. Make sure
that the marks are level with each other.

a. Types of Fasteners that can be used:

Drywall anchors.

NOTE: When using the drywall anchors

follow the instructions provided in the
Wall Anchor Kit.

Two Screws.

Combination of one anchor and one

screw.

NOTE: The wall anchor kit provided will
accommodate these combinations.

2. Use a Phillips head screwdriver to mount the

frame assembly on the wall. The frame as-
sembly must be securely mounted to the wall.
NOTE: For other surfaces, such as concrete,
different fasteners or anchors maybe re-
quired. These types of fasteners are not in-
cluded.

Base Mounted - Fig. 3

You may wall mount as a sconce or place on
provided base mount as shown in Fig.3 Make
sure frame is placed securely on both dowels
and base mount is secure.
Use caution in placement of unit as to avoid
unit from being knocked over. Make sure cord is
placed where it will not get caught or tripped on.

Locate mounting holes

approximately 66” (1.68m)
above floor

72679-04-21-2014

Paraclipse Fly Patrol™

Page 5

Ultraviolet Lamp/Cartridge Installation





Frame

Assembly

Lamp Socket

Fig. 4

Fig. 5

Fig. 6

Ultraviolet Lamp

Drive Spool

Cartridge

Motor Enclosure

Alarm Hole

Lamp and Cartridge Installation:

Note: Unit must be securely mounted to wall
or placed on base mount before you proceed
with the installation of Lamp & Cartridge.

1. Remove the ultraviolet lamp from the box.

Insert the lamp into the lamp socket by align-
ing the pins of the lamp with the light socket
and snap in firmly. (Fig. 4 & 5)

NOTE: It is recommended to replace the

ultraviolet lamp every eight months of use to
maintain optimum performance of the unit.

At eight monthe of continuous use the UV

output of the lamps have lose approximately
30% effectiveness and should be replaced.
After this time the lamp may still light but is no
longer emitting enough of the special UV light
frequency required for an effective insect
catch.

2. Rotate the drive spool of the cartridge in the

direction of the arrow shown on the drive spool
until the glue spans the full length of the car-
tridge. (Fig. 5)

3. Position the cartridge on the top of the motor

enclosure. Push the cartridge in until it stops.
(Fig. 5 & 6) NOTE: About 6 to 7 rotations will
be required.

Replacement Quantum Lamp Kit: part # 72489

Cartridge Alarm:

The Paraclipse Fly Patrol

has an out of paper

sensor that emits an audible beep when it is time to
replace the cartridge. The alarm is triggered when
the paper no longer covers the alarm hole in the top
of the motor enclosure. ( see Fig. 4)

To test the operation of the alarm follow these steps.

1. Plug the unit into the outlet

2. Carefully remove the cartridge. The alarm

should emit an audible beep.

3. Stop the alarm by installing a fresh cartridge.