Important safety instructions, Cartridge alarm & manual paper advance, Save these instructions – Paraclipse Insect Inn Ultra I User Manual

Page 3: Insect inn ultra

Advertising
background image

72670-3-11-2014

Save these instructions

Page 6

Cartridge Alarm & Manual Paper Advance

Cartridge Alarm:

The Insect Inn Ultra™ has an

out of paper sensor

that emits an audible beep

when it is time to re-

place the cartridge. (fig. 6)

The alarm is triggered when the paper no longer
covers the alarm hole in the top of the paper hold-
er plate. An electronic light sensor recognizes this
and begins to emit a high pitched beep.

Testing:

To test the operation of the alarm follow these
steps:

1. Plug the unit in to the outlet.

2. Carefully remove the cartridge. The alarm

should emit an audible beeping.

3. Stop the alarm by installing a fresh cartridge.

NOTE: If new cartridge is not available for
installation, unplug the unit to shut off the alarm
until a genuine Paraclipse replacement cartridge
is available.

Manual Paper Advance:


You can manually advance the tacky paper sur-
face by simply turning the right advance knob
clockwise until the desired amount of tacky paper
is available to catch insects. (fig. 7)
This maybe required when installing a new car-
tridge and advancing the paper due to heavy in-
sect catch.

Alarm Hole

Fig. 6

Fig. 7

Advance Knob

IMPORTANT SAFETY INSTRUCTIONS

This symbol is intended to alert you of the
presence of dangerous voltage within the
unit’s enclosure that maybe of sufficient mag-
nitude to constitute a risk of electrical shock.

This symbol is intended to alert you of
the presence of important operating
and maintenance instructions accom-
panying the unit.

Caution! To reduce the risk of electric shock, observe the following:

1. Do not remove the motor enclosure. No user serviceable parts are inside.

2. This product is intended for use indoors only! Do not use where it may be exposed to

water or direct sunlight (including roofed but open porches).

3. Disconnect the product from power supply when not in use, before servicing, cleaning,

or when changing lamps.

4. Use only Extension Cords marked SPT– 2, or equivalent. Its electrical rating must be at

least 120 V, 60 Hz, and 10 Amps. Use only 3-wire extension cords which have 3-prong
grounding-type plugs (See Fig. A), and 3-pole receptacles which accept product’s plug.
(See Fig. B) Replace or repair damaged cords.

5. Extension cords & devices for retaining an extension cord connection to the power sup-

ply cord are available.

6. Don’t abuse the cord. Never carry the product by the cord or yank it to disconnect it.

Keep the cord from heat, oil, and sharp edges.

7. Power supply cord are available.

CAUTION! To avoid risk of contamination, observe the following: Dead insects
are unsanitary. Use care in removing used cartridge.

Insect Inn Ultra

Page 3

72670-3-11-2014

SAVE THESE INSTRUCTIONS

Grounding Instructions: The product is equipped with an appropriate 3-conductor
cord and 3-prong grounding-type plug to fit the proper grounding-type receptacle.
To reduce the risk of an electric shock, the plug must be plugged into an appropri-
ate outlet that is properly installed and grounded. (See figure A). Consult a quali-
fied electrician if in doubt as to whether proper grounding exists.

Fig. A

Fig. B

GROUNDING PIN