Remy 42MT SSL Solenoids User Manual

Remy Generators

Advertising
background image

1




37MT, 41MT and 42MT STARTERS 12V and 24V SEMI-SOLID LINK SOLENOID INSTALLATION
INSTRUCTIONS

WARNING!!!!

ALWAYS USE PROPER EYE PROTECTION WHEN PERFORMING ANY MECHANICAL

REPAIRS TO A VEHICLE

– INCLUDING, BUT NOT LIMITED TO, ANY INSTALLATION AND OR REPAIRS TO

THE DELCO REMY STARTING MOTORS. FAILURE TO USE PROPER EYE PROTECTION CAN LEAD TO
SERIOUS AND PERMANENT EYE DAMAGE.

Only perform the mechanical functions that you are properly qualified to perform. Mechanical repairs that are
beyond your technical capabilities should be handled by a professional installation specialist.

NOTICE! FOLLOW ENGINE AND/OR VEHICLE MANUFACTURERS INSTRUCTIONS CAREFULLY WHEN
REMOVING AND INSTALLING THE STARTERS.

These instructions describe the removal process for 37MT, 41MT and 42MT Conventional and Semi-Solid Link
Solenoids and the installation procedures for Semi-Solid Link Solenoids.


IMPORTANT:
THIS PACKAGE INCLUDES TWO NEW MOTOR TERMINAL CONNECTOR STRAPS TO
REPLACE THE ONES ON THE STARTER]. ONE STRAP IS COMMON TO THE 37MT & 41MT AND THE
OTHER IS FOR 42MT ONLY. IT IS IMPORTANT TO USE THE CORRECT STRAP AS LABELED [See
illustrations, page 4]. THE STRAPS ON NEWER STARTERS MAY BE THE SAME AS THESE IN PACKAGE.

Determine the series of starting motor and solenoid type you are replacing. The motor series number is
stamped in the Series Block on the starter name tag and the solenoid part number is stamped on the
metal case of the solenoid.

Conventional solenoid part numbers will be 1115657 or lower (Follow instructions A)

Semi-solid link solenoid part numbers will be 1115663 or higher (Follow instructions B)

Fasteners, in this document, are referred to by wrench size rather than thread size.

DANGER!!!

Before replacing the solenoid, the starting motor must be removed and completely disconnected

from the vehicle. Disconnect the negative (-) battery cable before removing the starter electrical connections.

A. CONVENTIONAL SOLENOID REMOVAL INSTRUCTIONS

(See illustrations pages 3 & 4)

1. For older 42MT model

s, loosen 3/4” nut on solenoid motor terminal [1]. For 37MT, 41MT and newer 42MT

starters, loosen E8 Torx Head motor terminal screw [1*].

2. Remove E8 Torx Head screw [2] at field connection on starter frame.
3.

For older 42MT models, remove 3/4” nut from solenoid motor terminal [1]. For 37MT, 41MT and newer
42MT starters, remove E8 Torx Head solenoid motor terminal screw [1*].

4. Remove solenoid to motor field connector strap [3]. Dispose of old design connector strap.
5. For insulated models (flexible ground cabl

e not shown), remove top 3/8” nut and washer assembly from

ground terminal [5] of solenoid.

6. Remove flexible ground lead (not shown) from the solenoid ground terminal [5].
7. Remove three E8 Torx Head solenoid mounting screws [6].
8. Remove solenoid [7] from lever housing. Plunger and boot assembly [9] will remain on starter.
9. Remove access plug and gasket [4] from front of lever housing, ensuring gasket is removed.

10.

Remove 1/2” plunger nut [8], carefully so it does not drop into starter, while holding the plunger securely
to prevent rotation. Dispose of nut [8].

11. Remove plunger and boot assembly [9].


Instruction Sheet

10512652

17DE04 REV 0

Advertising
This manual is related to the following products: