NOTICE

- Only licensed Remy International, Inc. product and component parts should be used, and the use of other parts or modifications not approved

by Remy International, Inc. will void all applicable warranties. The failure to carefully follow these Installation Instructions, set forth above, will void all
applicable warranties. DELCO REMY is a registered trademark of General Motors Corporation, licensed to Remy International, Inc. Pendleton, IN 46064.
©

2012 Remy International, Inc. All rights reserved

2

Technical support: USA 800 854 0076, Mexico 01 800 000 7378, Brazil 0800 703 3526, South America 55 11 2106 6510 or visit
delcoremy.com

time on the brush plate and CE assembly by pulling the spring to allow them to get into the holder, assuring the same
position as removed and the armature is in place. Torque the brush screws to 2.26-4.52 Nm (20-40 lb in) for punched
holes or 3.62-5.20 Nm (32-46 lb in) for extruded holes.

6. Apply bearing type grease onto CE housing’s outer diameter where the o’ring is seated and apply a small amount of SAE20 oil

into the bushing area.

7. Install the CE housing, brush-plate and armature on the starter with the screws, assuring the same position as removed.
8. Attach the three (3) field leads to positive brushes with attaching screws for 12V, 24V & 32V models or two (2) field leads to

positive brushes with attaching screws for 64V models over the plug holes. Torque screws to 2.26-4.52 Nm (20-40 lb in) for
punched holes or 3.62-5.20 Nm (32-46 lb in) for extruded holes.

9. Install the three (3) plugs to the frame and torque to 8.13 Nm (72 lb in).

NOTICE! After repair and reassembly it is necessary, before installation on the engine, to check and adjust pinion
clearance. It is recommended the solenoid replacement instruction sheet, 10500262, be obtained from our website,
www.delcoremy.com
.

10. Reinstall starter and connect cables and other leads, as removed.
11. Reconnect the negative (-) cable at the battery.

50MT 64VOLT GRAPHICS: Refer back to the "disassembly and brush cleaning procedures on page one (1) for assistance.

Note: Cleaning procedures, page 1, should be reviewed along with the graphics for clarity.

One of three (3) positive
Brush access holes

Remove armature to clean brush
dust from frame with a nylon brush

Scrape hardened brush dust from
recessed screws in the brush plate

Scrape hardened chunks of brush dust
from the positive brush insulators

Scrape hardened brush dust from inside
the CE frame, but do not scrape through
the black CE frame paint coating the
frame

Remove three (3) screws to
separate brush holder assembly
from the CE frame