Recommended wire chart, Wiring, Negative ground system positive ground system – Remy REPLACE D.C. GENERATORS WITH A 30SI ALTERNATOR User Manual

Page 2

Advertising
background image

Technical support: USA 800 854 0076, Mexico 01 800 000 7378, Brazil 0800 703 3526, South America 55 11 2106 6510 or visit
delcoremy.com

NOTICE

- Only licensed Remy International, Inc. product and component parts should be used, and the use of other parts or modifications not approved

by Remy International, Inc. will void all applicable warranties. The failure to carefully follow these Installation Instructions, set forth above, will void all
applicable warranties. DELCO REMY is a registered trademark of General Motors Corporation, licensed to Remy International, Inc. Pendleton, IN 46064.
©

2012 Remy International, Inc. All rights reserved

2

1965400 Ammeter Package

WIRING

A. Connect 30SI alternator per wiring diagram.

1. It may be necessary to replace output and ground terminals with new terminals having 1/4“ holes.

2. Charging circuit wire size is important in order to maintain batteries in charged condition. If old wiring does not conform to length

vs. size covered in “Recommended Wire chart”, it must be replaced.

3. Any old wiring not used should be tied down and expose terminals taped.
4. The regulator for the 30SI is mounted inside; therefore, the old regulator may be removed and discarded.
B. Voltage Adjustment
1. On 15 cell (30 volt) system change voltage adjustment cap to number 3 position.

2. Leave voltage adjustment cap “as is” on 12, 24 and 32 volt systems.

Re-connect batteries and start engine. When initially starting the engine, it may be necessary to momentarily increase engine speed to
approximately 1000 rpm for the 30SI to “turn on” and charge at idle speed.

WIRING DIAGRAMS FOR 30SI DELCOTRON ®ALTERNATOR


























Optional Voltmeter
Instead of Ammeter

NEGATIVE GROUND SYSTEM

POSITIVE GROUND SYSTEM

1965400 Ammeter Package

Optional Voltmeter

Instead of Ammeter

RECOMMENDED WIRE CHART

SYSTEM

V O L T A G E

S I Z E v s . L E N G T H

12 VOLT

UP TO 5 FT.

No. 8

5

F T . T O

8 F T .

No. 6

8

F T . T O

1 2 F T .

No. 4

1 2

F T . T O

1 9 F T .

No. 2

24 & 32

UP TO 6 FT.

6

F T . T O

1 1 F T .

1 1

F T . T O

2 1 F T .

2 1

F T . T O

2 5 F T .

V O L T

No. 8

N o - 8

No.6

No.4

INSULATED SYSTEMS- TOTAL
LEADS (1), (2) & (3) TO SELECT
PROPER WIRE SIZE VS LENGTH.

GROUNDED SYSTEMS-TOTAL
LEADS (1) & (2) TO SELECT
PROPER WIRE SIZE VS
LENGTH. (3) & (4) LEADS
SHOULD BE No. 8 WIRE SIZE.