PRECAUTIONS

• CHECK INFLATION AT LEAST ONCE A DAY!

• DO NOT use any supply of compressed air, oxygen, or other gases to inflate your

cushion. The use of any inflation device other than the supplied hand pump may dam-

age the cushion and void the warranty.

• UNDER-INFLATION: DO NOT use an under-inflated cushion. Using a cushion that

is under-inflated reduces or eliminates the cushion’s benefits, increasing risk to the

skin and soft tissue. If your cushion appears under-inflated or does not appear to be

holding air, make sure that the valve is closed by turning it clockwise. If your cushion

is still not holding air, contact your clinical caregiver, distributor, or ROHO, Inc. im-

mediately.

• OVER-INFLATION: DO NOT use an over-inflated cushion. Using an over-inflated

cushion will not allow you to sink into the cushion and will reduce or eliminate the

cushion’s benefits, increasing risk to the skin and other soft tissue.

• CUSHION AND COVER ORIENTATION: Product must be used with the provided cover

and with the air cells facing up. If the cover is not used correctly or if the cover is the

wrong size, it may reduce or eliminate the cushion’s benefits and could increase risk to

the skin and other soft tissue.

• DO NOT use on top of or in conjunction with another cushioning product.

• OBSTRUCTIONS: DO NOT place any obstructions between the user and the cushion

as it will reduce product effectiveness.

• PRESSURE: Changes in altitude may require adjustment to your cushion. Check your

cushion when changing altitude of 1,000 feet (300 meters) or greater.

• PUNCTURE: Keep your cushion away from sharp objects which may puncture the air

cells and cause deflation.

• DO NOT expose your cushion to high heat, open flames or hot ashes.

• CLIMATE: If a cushion has been in temperatures (less than 32ºF/0º C) and experienc-

es unusual stiffness, allow the cushion to warm to 72ºF/22ºC before inflation or use.

• HANDLING: DO NOT use the valve to carry your cushion. Use the carrying handle on

the provided cover.

• DO NOT use your cushion as a water flotation device (e.g. a life preserver).

• OZONE GENERATORS: Prolonged exposure to ozone will degrade materials used in

your HARMONY cushion and may affect the performance of your product and invalidate

the product warranty. Avoid prolonged exposure of the cushion to direct sunlight or

other sources of ultraviolet (UV) light.