Electrical Specifications

Acoustic Operating Principle:

Electro-dynamic pressure gradient

Polar Pattern:

Figure-8

Generating Element:

2.5 micron aluminum ribbon

Frequency Range:

30HZ – 15,000HZ ±3dB

Sensitivity:

-49dBv Ref 1 v/pa

Output Impedance:

300 Ohms (nominal) balanced

Rated Load Impedance:

> 1500 Ohms

Maximum SPL:

> 135dB

Output Connector:

Male XLR 3 pin

(Pin 2 Hot)

All Royer monaural microphones are available in matched pairs.

Mechanical Specifications

High grade Neodymium magnet assembly in Royer’s patented Flux-Frame transducer
1.5” x 3/16” x 2.5-micron ribbon assembly

Stainless steel internal baffle and dampener

Weight:

244 grams (8.6 ounces)

Weight with Case:

21.1 ounces

Dimensions:

158mm x 25mm (6.13” L xW)

Finish:

Dull Satin Nickel or Matte Chrome

Accessories:

Protective wood case, protective mic sock

Optional Accessories:

Shock mount, popscreen