Warning, Commercial systems – Sanuvox S1000FX User Manual

Page 2

Advertising
background image

COMMERCIAL SYSTEMS

Before installing or performing maintenance or service

on the purifier, DISCONNECT from main power.

Electrical shock can cause injury or death.

Never expose eyes or skin to ultraviolet light from any
source. The Purifier MUST be DISCONNECTED from

power source before performing maintenance or

service. Personal injury may result.

Do not touch Lamp glass without gloves. Reduced

performance of Lamp may result. Clean Lamp after

handling.

Use only specified replacement Lamps with your

Purifier. Use of an incorrect Lamp can result in damage

to the Purifier and/or Lamp.

WARNING

WARNING

WARNING

The UV Lamp contains a small quantity of mercury. If a

Lamp breaks, clean and dispose of with care.

WARNING

WARNING

SAFETY CONSIDERATIONS

When servicing UV purification-filtration equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety
precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves.

GENERAL

The S1000FX-GX is a combination Ultraviolet - Filter Air Purification System. The S1000FX-GX UV Germicidal Photo-Oxidation process
(UVC/UVV) destroys bio-chemical contaminants such as mold, viruses, bacteria, germs, chemicals, cigarette smoke, VOC’s and odors. The
S1000FX-GX is also equipped with two 1” pre-filters and a MERV 14 (95%) efficiency filter. 99.97% HEPA Filter available. Details below.

OPTIONS

Depending on the model ordered, there may be additional options available.

SUBKITCROS1000: Clean Room Option. Incl. (1) HEPA 99.97% Filter (1) BST120W5 or (1) BST230W5 Secondary ballast (1) secondary
LMPRGJ160 31.5” UVC ‘J’ Lamp.

SUBKITVOCS1000: VOC Kit incl. (1) VOC Sensor (1) BST120W5 or (1) BST230W5 secondary ballast (1) secondary LMPRXJ160 UVV ‘J’
Lamp.

MSCFTR12: An optional 99.97% efficient HEPA filter (20” x 20” x 4”)

MSCFTR12-1: An optional 99.97% efficient HEPA filter (20” x 20” x 5”)
biological contaminants.

1-888-726-8869 www.sanuvox.com SANUVOX TECHNOLOGIES INC. COPYRIGHT 2010 v.1.0

A

B

C

D

E

F

G

H

I

A. 1 x pair of 8” inlet collars
B. 1 x pair of 8” outlet collars
C. Aluminum Reflecting Chamber
D. 31.5” UV ‘J’ Lamp
E. Ballast

F. 2 x 1” Pre-Filter
G. Main Filter (MERV 14 or opt. HEPA)
H. Power
I. Doors
J. Safety Cut-Off Switch

J

Advertising