Installation - continued – Sanuvox COILCLEAN IL User Manual

Page 5

Advertising
background image

INSTALLATION - continued

UV SYSTEM ‘ON’

/ SISTEMA UV 'ENCENDIDA'

UV LAMP TO BE REPLACED

/ LÁMPARA UV QUE SER REEMPLAZADO

UV LAMP FAILURE

/ FALLOS DE LA

LÁMPARA UV

NO POWER (LED OFF)

/ NO HAY ENERGIA

(LED APAGADO)

STATUS

UV LAMP 2

UV LAMP 1

Cover

Removed

Figure A.

Ballast

Mounted

to the wall

Figure B.

UV Lamp Boot

Ballast Box Installation

9. Remove the 4 x phillips head screws from the ballast box cover. Mount the ballast box on a wall
or other hard surface, attache using the 2 holes in the center of the ballast box.
Be careful not to damage the wiring.

Wiring Ballast Box to the UV Lamp(s)

10. Depending on the ballast box there may be one or two ballasts incorporated into the
Ballast Box (depending on how many units were ordered). The wire harness comes
with 20 feet of TEFLON wire set per ballast.

11. In order to facilitate running the wire set from the ballast to the UV Lamp, the GAYNOR plug
and Lamp Boot are made to be installed after the wires have been run. To install: First slide the
two Lamp wires through the UV Lamp Boot and then push each of the two wires into the white
GAYNOR plug DIAGONALLY. Example: If one wire is pushed into the TOP RIGHT hole than
the second wire should be pushed into the BOTTOM LEFT hole. The wire will automatically
catch once inserted into the GAYNOR plug.

12. Carefully secure the white GAYNOR Plug to the end of the UV Lamp. NOTE: The GAYNOR Plug fits on two of four ways. If the
plug does not fit, just rotate the plug. The UV Lamp Boot is designed to seal the connection between the plug and the UV Lamp
as to reduce the possibility of moisture penetrating to the connection. NOTE: The UV Lamp Boot does not cover
the entire end- cap (approx. 3/4").

Wiring to POWER

13. The CoilClean IL is available in different voltages.
With cover removed, pull the white (neutral) and black (hot) from the
round knock-out at the bottom of the ballast box. CONNECT TO
POWER using the included ORANGE wire connectors.

Using the COUPLER to join multiple 3/4" Support Rods

The Coupler Tube can be inserted between two or more Support Rods or 3/4" EMT conduit allowing the Support Rods to be
extended to desired lengths.

1. I

nsert Inner Tube halfway inside one Support Rod

2. Using a 1/4" hexagon drill, screw one self taping
screw. The hole in the Support Rod is pre-drilled

3. Insert the other half of the Inner Tube into the
other Support Rod and follow the instructions in step 2

4. The completed assembly with the Inner Tube Coupler joining two Support Rods

5

Wire Set

from Ballast

Push each of the two wires into the white
GAYNOR plug DIAGONALLY

UV Lamp 4 pin end

Advertising