Disconnect power and remove the 3 Rear Panels.

Line up purifier so that the attachment holes on the purifier

frame line up with the holes on the rail of the Bard.

Use sheet metal screws to attach the purifier to the Bard unit

at the attachment holes and to hold the Center Brace.

Route the cable into the electrical box on the side

of the Bard Unit.

Wrap the foam insulation above the rail with

aluminum foil to protect the foam.

The electrical connections are made to the Blower assembly as follows:
Connect a jumper wire with a spade terminal attached to the 220 Volt terminal Cable from UV Purifier.

220 Volt connection from Butt Connector.

Connect the Green ground wire of the cable to the ground lug terminal on the Bard Unit.
Install a spade terminal on the Black wire and connect.
Connect the white wire to the white wire of the cable using a butt connector.

Cover the plastic drain hose with

aluminum foil. Make sure that the drain

functions properly. Replace Rear covers

on the Bard unit.

Apply power.

When the Bard blower starts, you will see

the glow from the front of the Coil.

Sanuvox CoilClean B30X UV Air Purifier / CoilCleaner

A full line of Residential & Commercial UV Air Purifiers are available. 1-888-SANUVOX www.sanuvox.com

patented technology

easy installation

controls pollutants

scientifically proven

cost effective

mold - bacteria - viruses - smoke - odors

Center Brace

Make sure the cut-off switch

is free and is not obstructed.

220V connection

from Butt Connector

Cable from UV Purifier

To 220V Terminal

Cable

Butt Connector

220 Volt Terminal

Ground Lug

Ground Wire

Advertising