页 11, Lithium battery(lipo/life/liion)program, Storage' control of lithium battery – SkyRC 6x80+ Blue Version Charger User Manual

Page 11: Discharging lithium battery

Advertising
background image

Current
voltage
battery

Supplied
capacity

Charge
current

Charging
time

Number
of
cells

identical you can start charging process. If
not, press button to go back to previous
screen to recheck the number of cells of the
battery pack before going ahead.

This screen shows the real-time status
during charge process. Press button once to
stop the charge process.

'STORAGE' CONTROL OF LITHIUM BATTERY

This program is for charging or discharging Lithium battery which will
not be used for long time. The program will determine to charge or
discharge the battery to certain voltage depending on the voltage of the
battery at its initial stage. They are different from the type of the battery,
3.75V for LiIo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage
of battery at its initial stage is over the voltage level to storage, the
program will start to discharge.

- +

- +

> 3 seconds

At this screen, you can set up the current
and voltage of the battery pack. Charging
and discharging will make the batteries
come to the voltage level of storage state.

This screen displays the number of cells you
set up and the processor detects. R shows
the number of cells detected by the charger
and S is the number of cells set by you at
the previous screen. If both numbers are
identical you can start charging process. If
not, press Mode/Stop button to go back to

SELECT

SELECT

Mode
Stop

Press
Dial

Press
Dial

18

19

6X80 Plus

6X80 Plus

LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM

Number
of
cells

Elapsed
time

Charge
or discharge
current

Supplied
capacity

Current
voltage
battery

This screen shows the real-time status
charging. Press Mode/Stop button once to
stop the charge process.

previous screen to recheck the number of
cells of the battery pack before going ahead.

DISCHARGING LITHIUM BATTERY

Number
of
cells

-

elapsed
time

+

Battery
voltage

Discharged
capacity

discharge
current

> 3 seconds

The value of discharge current on the left
can not exceed 1C, and the value on the
right can not be under the voltage
recommended by the manufacturer to avoid
over discharging. Press and hold the dial for
3 seconds to start discharging.

This screen shows the real-time status of
discharging, you can press Mode/Stop
button to stop discharging.

This screen displays the number of cells you
set up and the processor detects. R shows
the number of cells detected by the charger
and S is the number of cells set by you at
the previous screen. If both numbers are
identical you can start charging process. If
not, press Mode/Stop button to go back to
previous screen to recheck the number of
cells of the battery pack before going ahead.

Mode
Stop

SELECT

- +

SELECT

Press
Dial

Press
Dial

Press
Dial

LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM

Advertising