Compressor hold control, 3 compressor hold control – Sonnox Oxford Dynamics User Manual

Page 21

Advertising
background image

4.7 Timing Functions

4 COMPRESSOR

4.7.3 Compressor Hold Control

The hold control varies the amount of time between a reduction of levels above the

threshold and the onset of the release time. It provides a period after gain reduction

where a slower rate of recovery occurs.

hold = nearly min

hold = intermediate position, release = min

hold = 75% of max

The above three diagrams show the action of the hold control from nearly minimum to
75% of maximum, with an intermediate position with the release set to minimum. When

the compressor is in recovery after a loud passage, the full value of the release setting
time is reached only gradually over the period of the hold time.

This produces an extended period when the release time is maintained at slower rates in

order to allow faster gain recovery without excessive distortion at low signal frequencies.
Since the release time is effectively multiplied by the hold time, very long total gain
recovery times can also be obtained by using the release control in conjunction with the
hold control.

www.sonnox.com

21

Go to contents

Advertising