Troubleshooting – Sonodyne AMC+60 User Manual

Page 8

Advertising
background image

TROUBLESHOOTING GUIDE

Trouble

Likely Cause

Remedy

Power LED not on

Power not reaching amplifier

Check power switch is on

Check mains connection

Check mains fuse

Distorted sound

Output is short circuit

Input is overloaded

Output is being over driven

Bass control is turned up

Check speaker loads for shorts

Reduce input level at source

Reduce volume levels on front panel

Reduce Bass control level

No sound but amp is on

Volume controls down

Amplifier has overheated
(AMC

+

60, AMC

+

120 AMC

+

250 only)

DC fuse(s) blown

Check volume controls

Check for obstructions above and below
Make sure the amplifier is well ventilated

Refer product to local Australian Monitor dealer

No sound from channels 2 and 3

Priority function is being used

Remove signal (disconnect input) from channel 1 OR
Disable priority function (see Internal Adjustments)

Tones do not sound when triggered

Tone generator module not installed

Purchase optional Tone generator module

PAGE 8

AMC

+

SERIES INSTALLATION AND OPERATION MANUAL

TROUBLESHOOTING

Advertising