Installation – SOR 1510 Side Mounted Level Switch User Manual

Page 2

Advertising
background image

2/8

Form 451 (11.13) ©SOR Inc.

Installation

MD Remote Option

(includes plundger, 20 foot cable and two crimps.)

 Screw plunger to the top of unit.

 Thread the 20’ cable through the hole in plunger and create a 14 inch top loop as

shown below.

At the bottom of the cable, a second loop can be created as a handle for actuation at

the desired length.

The unit may be mounted in any of the following installation arrangements:
 1-1/2” NPT half coupling (No full coupling).
 2” NPT full coupling. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)
 2” NPT pipe tee. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)
 Optional flanged mounting.
 Optional chamber mounting.

Linear = mm/inches

Drawing 0098636

REMOTE MANUAL CHECK

MD OPTION

CRIMP

REMOTE CABLE

CREATE HANDLE AT DESIRED LENGTH

TOP 14” LOOP

PLUNGER