OWNER’S MANUAL 1186531 REV 6 (9/14)

PAGE 17

OF 22

I

NFRARED

C

HEESE

M

ELTER

T

ROUBLESHOOTING

WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS

EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT.

HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE

SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.

NOTICE

Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified

technician, or if other than genuine Southbend replacement parts are installed.

Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized Parts

Distributor or a Southbend Authorized Service Agency.

When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.

In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with

information listed on the serial plate.

T

ROUBLESHOOTING

Problem

Look for - 1

- Not enough heat

- Low pressure in gas supply

- Restriction in gas piping and/or valves

- Misalignment of burner orifice tube

- Clogged burner orifice

- Incorrect burner orifice

- Too much heat

- Incorrect orifice.

- Defective or incorrectly set pressure regulator.

- Burner flame fluttering or has excessive blue haze

- Obstruction of combustion-air intake on rear of broiler

- Exhaust gases blocked by objects sitting on top of broiler

- Low pressure in gas supply

- Misalignment of orifice tube

- Burner flame popping (infrared)

- Cracked or loose ceramic.

- Slow (or no) burner ignition

- Pilot flame out of adjustment

- Pilot alignment out of adjustment

- Thermocouple not in pilot flame (for units with the flame-failure option)

- Pilot outage

- Pilot flame out of adjustment

- Draft condition

- Pilot orifice clogged

- Incorrect pilot orifice

- Thermocouple not in pilot flame (for units with the flame-failure option)