Installation – Southbend 20108RSB User Manual

Page 20

Advertising
background image

20

Printed in USA 12/02

Refrigerated Base-Remote © 2002

INSTALLATION

UNPACKING

Note: Before unpacking the unit, note any crate markings
and check for damage to crating. Notify the carrier if there
should appear to be damage to the unit.

The unit is shipped directly from the manufacturing factory
securely fastened to a single pallet then protected by an
external wrapping.

1. After inspection, carefully remove all external

wrappings and other protective coverings.

2. Review the installation section of the manual

completely prior to installing the unit.

3. Discard crating materials.

INSTALLATION

1. Before moving the unit to the installation sight, double-

check passageways to ensure that the unit will move
through without modification.

Note: In certain instances, it may be necessary to remove
the drawers. This will allow the unit to fit through tighter
spaces.

2. Position the unit to allow for sufficient ventilation.

Typically, approximately 3" clearance from walls and
other equipment is sufficient.

3. Level the cabinet from front to back and side to side.

This is important so that the cabinet will not be pulled
out of square.

4. Evaporator coil drain lines are factory installed and are

either plumbed into a condensate evaporator pan or
the condensate evaporative base of the condensing
unit

i

to eliminate the need for exterior plumbing. Make

certain that the drain outlet is located such that the
condensate falls into the pan or base. On units with
remotely located refrigeration, the condensate
evaporator pan is optional.

5. Check the door gasket to make certain that it is sealing

properly to the cabinet.

6. Before applying electrical power to the unit, you should

first check the electrical characteristics of the
condensing unit to ensure that they agree with those of
the electrical supply source.

CAUTION

Low or excessive voltage can severely damage the
electrical system.

Note: Adjusting any valves or controls on the system is not
necessary and may void your warranty. All valves and
controls have been set by the factory.