SpectraCal Panasonic 2011-2012 WT50 User Manual

SpectraCal Computer Accessories

Advertising
background image

Panasonic

VT30/DT30/D30, VT50/WT50 (US/NA models)

CalMAN Setup Guide


CalMAN automatically calibrates the Panasonic VT30/DT30/D30/VT50/WT50 US/NA model display’s two
point grayscale controls, and, on VT models only, 10 point grayscale controls and CMS color gamut
controls. The display’s two custom picture modes, ISF Day and ISF Night, can each be calibrated with
individual picture menu adjustments, grayscale adjustments, and CMS adjustments (VT models only).

Recommended CalMAN Workflows:
DT30/D30/WT50

HT Basic or SI Basic workflow to optimize Picture controls and calibrate two point grayscale RGB
balance controls.

VT30/VT50

HT Advanced or SI Advanced workflow to optimize Picture controls and calibrate 10 point
grayscale RGB balance controls and CMS color gamut controls.


Recommended Test Patterns:
Plasma displays exhibit power supply luminance limiting with high brightness, high APL test patterns.
This can cause incorrect luminance measurements. To avoid this situation with plasma displays, use test
patterns with the smallest window size available from your test pattern source. Under Window Size, on
the Source Settings panel, select the smallest window size that works with your color meter.

Required Panasonic Firmware:

VT30 – 2.220

VT50 – 1.170


Panasonic Control Connection:
VT30/DT30/D30

3.5mm jack to DB9 female adapter, plus

DB9 female to DB9 female straight through RS-232 cable (pin2 to pin2, pin3 to pin3)

VT50/WT50

Ethernet straight through (standard) cable for direct connection, or

Wireless (Wi-Fi) connection


Panasonic Setup Process:
To connect the calibration computer to a VT30/DT30/D30 with a serial cable:

1. Connect a 3.5mm jack to DB9 female adapter and a DB9 female to DB9 female straight through

RS-232 cable between the display and the CalMAN computer (if necessary, use a USB to serial
adapter).

Advertising
This manual is related to the following products: