Troubleshooting guide – Dimplex DWF1146GP User Manual

Page 12

Advertising
background image

12

www.dimplex.com

Troubleshooting guide

Problem

Possible Cause

Corrective Action

Circuit breaker trips or fuse

blows when unit is turned on.

Improper circuit current

rating.

Additional appliances may exceed the current rating of the

circuit breaker or fuse. Plug unit into another outlet or install

on a dedicated 15-amp circuit. If problem persists, contact

technical support.

Unit turns on or o ff by itself.

1. Remote control has

a similar frequency to

another remote.

2. Radio frequency

disturbance from outside

sources.

1. Re-initialize remote or move unit out of range of

interference.

2. Change frequency of other device if possible.

3. If problem persists, contact technical support.

Lights dim in room while the

unit is on.

Unit is drawing close to

circuit current rating.

Move the unit to another outlet or install unit on a

dedicated 15-amp circuit.

Power cord gets warm.

1. Normal operation.

2. Improper extension cord

in use.

1. The power cord may get slightly warm to the touch

when the heater is on.

2. Ensure any extension cord used is rated for 1875 W

and 14 AWG.

3. If problem persists, contact technical support.

Fireplace does not turn on.

1. Unit is not plugged in.

2. Circuit breaker has

tripped.

3. Improper operation.

4. Remote not initialized.

5. Depleted batteries in

remote.

1. Plug unit in to outlet.

2. Check electrical panel.

3. Refer to instruction manual.

4. Initialize the remote control.

5. Install new battery into remote.

6. If problem persists, contact technical support.

Flame frozen or shutters.

Contact technical support.

Flame not bright or not visible.

Burned out light bulbs.

Replace light bulbs.

Log set dim or not glowing.

Burned out light bulbs.

Replace light bulbs.

Light leaking from log set.

1. Log set not installed

properly.

2. Defective log set.

1. Check log set for proper fit.

2. Contact technical support..

heater is not turning off .

1. Improper operation.

1. Refer to instruction manual.

2. If problem persists, unplug unit and contact technical

support.

heater is not turning on.

1. Improper operation.

1. Refer to instruction manual.

2. If problem persists, unplug unit and contact technical

support.

heater emits an odor.

1. Normal operation.

1. Normal operation is when the heater emits an odor

for a brief period after the heater is initially turned on.

The heater is burning off any dust accumulated during

manufacturing or operation.

2. If problem persists, unplug unit and contact technical

support.

heater fan turns on but heater

lacks heat.

1. Improper operation.

2. Normal operation.

1. Refer to instruction manual.

2. Normal operation.

3. If problem persists, unplug unit and contact technical

support.

heating element is glowing red. 1. Normal operation.

1. Small glowing sections of the element are considered

normal.

2. If larger glowing sections are causing the heater to trip

the thermal cutout, unplug unit, discontinue use and

contact technical support.