SurgeX SA-82 User Manual

Connections

Advertising
background image


SA-82-AR / XF2-AR Quick Start Guide

Page 1

Connections



1. Connect Network. The SA-82-AR/XF2-AR supports 10/100

Ethernet using the cable supplied, or other suitable
unshielded twisted pair (Cat 5) cabling.

2. Connect Powered Equipment. Connect the device to be

powered On and Off to the duplex receptacle located on the
rear panel. If the connected equipment has a Power switch,
leave it in the On position to allow the SA-82-AR/XF2-AR to
control the power.

IMPORTANT: Ensure that the total combined load of all
controlled devices does not exceed 8 Amps.


3. Connect Power Mains. Connect one end of the supplied

power cord to the IEC connector labeled “AC Input”, and the
other end to a properly grounded AC outlet.



Web Browser Access

Factory Default IP Address: 192.168.1.254

Factory Default Security Credentials:

Role

Username

Password

Administrator

admin

admin

User

user

user



To access the SA-82-AR/XF2-AR from the default IP Address,
the PC must be on the same local network (IP address of
192.168.1.nnn). If it is not, change the IP address using one of the methods on the following
page.

After pointing a web browser to the IP address of the SA-82-AR/XF2-AR, enter the
Administrator Username and Password to access the complete Setup features. Entering the
User credentials will enable access to only the power control. Once the user is validated, the
Control and Status page is displayed.

Click on the appropriate button to control the power. During power cycling, the Power Status bar
will indicate the temporary status, and will have a blue background. Once the cycle is complete,
the status bar will revert to its original condition.