SurgeX CM-1115-RT-AR User Manual

Connections

Advertising
background image

CM-1115(20)-RT-AR Quick Start Guide

Page 1

Connections

1. Connect Network. The CM-X-AR supports 10/100 Ethernet

using the cable supplied, or other suitable unshielded twisted
pair (Cat 5) cabling.

2. Connect Powered Equipment. Connect the device to be

powered On and Off to the duplex receptacle or attached
outlet strip. If the connected equipment has a Power switch,
leave it in the On position to allow the CM-X-AR to control the
power.

IMPORTANT: Ensure that the total combined load of all
controlled devices does not exceed 15 (20) Amps (CM-1115-
X-AR/CM-1120-X-AR).

3. Connect Power Mains. Connect the attached power cord to a

properly grounded AC outlet. CM-1120-X-AR models require a
NEMA 5-20R outlet.



Web Browser Access

Factory Default IP Address: 192.168.1.254

Factory Default Security Credentials:

Role

Username

Password

Administrator

admin

admin

User

user

user



To access the CM-X-AR from the default IP Address, the PC must be on the same local network (IP
address of 192.168.1.nnn). If it is not, change the IP address using one of the methods on the
following page.

After pointing a web browser to the IP address of the CM-X-AR, enter the

Administrator Username and Password to access the complete Setup features. Entering the User
credentials will enable access to only the power control. Once the user is validated, the Control and
Status page is displayed.


Click on the appropriate button to control
the power. During power cycling, the
Power Status bar will indicate the
temporary status, and will have a blue
background. Once the cycle is complete,
the status bar will revert to its original
condition.