e. Connect Filter to Outlet: Plug the Filter input power cord into a properly grounded

and compatible branch circuit outlet. The plug is used as the disconnect device.

Please Note: Do not plug the Filter into a re-locatable power tap.

i. If the branch circuit outlet is correctly wired and the magnitude of the line

voltage is acceptable (between 105 and 140 V

RMS

for 120V products, or

between 190 and 260V

RMS

for 208/230V products), power will be connected

to the outlets of the Filter and the Green

“System On” LED will illuminate.

Your equipment is now protected and installed correctly. You may now turn
all connected equipment back on.

ii. If the branch circuit outlet is incorrectly wired, the Red

‘Wiring Fault” LED will

illuminate and the LCD will display specific wiring fault information. If this
occurs, contact a licensed electrician to correct the outlet wiring. Refer to
Section III: Hardware/EnVision PCS Filter, for LCD EVENT MONITOR
display details.

iii. If neither

“System On”, nor the “Wiring Fault” LED illuminates, there is either

no voltage at the receptacle or the magnitude of the line voltage is not
acceptable (less than 105 V

RMS

or above 140 V

RMS

for 120V products, or

less than 190 V

RMS

or above 260 V

RMS

for 208/230V products). If the

magnitude of the line voltage is not acceptable, specific information will be
displayed on the LCD. If this occurs, contact a licensed electrician to trouble-
shoot the abnormal voltage condition. Refer to Section III:
Hardware/EnVision PCS Filter, for LCD EVENT MONITOR display details.

1. You may also need to verify that the Filter is operating properly.

To test, plug the Filter into a known properly functioning outlet. If the
“System On” LED still does not illuminate in the functioning outlet,
contact ESP at 1-800-645-9721.





CAUTION – Do not install this
device if there is not at least 10
meters (30 feet) or more of wire
between the electrical outlet and
the electrical service panel.

La PRUDENCE - n’installe pas cet
artifice s’il n’y a pas au moins 10
mèters (30pieds) ou plus de fil
entre l’issue èlectrique et le
comitè de service èlectrique.

PRECAUCIÓN: No instale este
dispositivo si no hay por lo menos
10 metros (30 pies) de cable entre
el tomacorriente y el panel de
servicio eléctrico.

Advertising
This manual is related to the following products: