8

d. ACA

Range

Resolution

Accuracy

Overload Protection

400µA

0.1µA

±0. 8% of reading,

Fuse

4000µA 1µA

±3 digits

0.5Amp/600V

40mA

0.01mA

400mA

0.1mA

e. OHM (Resistance,

)

Range

Resolution

Accuracy

Overload Protection

400

0.1

±0. 5% of reading,

600V DC or

4k

0.001k

±3 digits

AC Peak

40k

0.01k

400k

0.1k

4M

0.001M

±1% of reading,

40M

0.01M

±3 digits

f. Diode Test

Test Voltage

Max Test Current

Over Load Protection

3V

Approx. 30µA

600 V DC or Peak AC

g. Continuity Buzzer

Test Voltage

Threshold

Over Load Protection

3V

< 50

600 V DC or Peak AC

h. General Specifications

Max. Volt. between

1000V

any Input and Ground
Fuse Protection

mA: 0.5Amp/600VAC

Display Type

4,000 Count, 2 times per second update

Operating Temp.

0° to 40°C (32° to 104°F)

Storage Temp.

-10° to 50°C (14° to 122°F)

Relative Humidity

0% to 80%

Power Supply

2 Each 1.5 Volt “AA” Batteries

Battery Life

200 hrs. Typical

Size (H x L x W)

33mm x 86mm x 187mm (1.3in x 3.4in x 7.4in)

Weight

340g (12oz)

3.

Specifications

IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2

a. DCV

Range

Resolution

Accuracy

Impedance

400mV

0.1mV

±0.3% of reading,

10M

4V

0.001V

±3 digits

40V

0.01V

400V

0.1V

1000V

1V

b. ACV (45 to 450 Hz)

Range

Resolution

Accuracy

Impedance

4V

0.001V

±0.8% of reading,

10M

40V

0.01V

±3 digits

400V

0.1V

750V

1V

c. DCA

Range

Resolution

Accuracy

Overload Protection

400µA

0.1µA

±0.8% of reading,

Fuse

4mA

0.001mA

±3 digits

0.5Amp/600V

40mA

0.01mA

400mA

0.1mA

9

UL 3111-1

*Warning: Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.

Advertising